![YOKOGAWA AE100D Скачать руководство пользователя страница 133](http://html.mh-extra.com/html/yokogawa/ae100d/ae100d_instruction-manual_911083133.webp)
IM 1E7B0-02E
12-2
12. EXPLOSION PROTECTED TYPE INSTRUMENT
(6) Data Plate
TOKYO 180-8750 JAPAN
AFTER DE-ENERGIZING, DELAY
10 MINUTES BEFORE OPENING.
WARNING
ENCLOSURE : IP67
ELECTRODE CIRCUIT Um : 250V ac/dc
0344
2G
Tamb.
FLUID PRESS
FLUID TEMP.
IM: User's Manual
MAGNETIC FLOWMETER
STYLE
30VDC 0.2Amax.
MODEL
SUFFIX
SIZE
METER
FACTOR
SUPPLY
CURRENT
OUTPUT
PULSE
OUTPUT
FULLSCALE
LINING
MATERIAL
ELECTRODE
MATERIAL
ACCURACY
RATING
No.
L
H
m
4-20mA
(0-750
Ω
)
(JIS B7554)
-0.1 MPa MIN. (SEE IM)
12.5
DC
V
+60
°
C MAX. (SEE IM)
MAX.PROCESS TEMP.(
°
C) : +70 +85 +120 +130
EEx dme[ia]IIC T6...T3
TEMP.CLASS : T6 T5 T4 T3
No. : KEMA 02ATEX2022
SEE THE NOTES AT BELOW
AND SEE IM
Made in Japan
VAC
47
–
63 Hz 36 VA 12.5
MODEL : Specified model code
SUFFIX : Suffix codes of the model code
STYLE : Specified style code
SIZE : Nominal size of apparatus
METER FACTOR : Sensor constant number of apparatus
SUPPLY : Power supply voltage of apparatus
FULL SCALE : Meter range
CURRENT OUTPUT : Output signal of apparatus
PULSE OUTPUT : Output signal of apparatus
LINING MATERIAL : Material of liner
ELECTRODE MATERIAL : Material of electrodes
ACCURACY RATING : Accuracy of apparatus
FLUIDTEMP. : Fluid temperature of apparatus
FLUIDPRESS : Fluid pressure of apparatus
Tamb : Ambient temperature
No. : Manufacturing serial number
CE : CE marking
ExII 2G : Group II Catergory 2 Gas atomosphere
KEMA No. : KEMA 02ATEX2022 : Certificate number
EExdem[ia]IICT6...T4 : Protection type and temp. class
ELECTRODE CIRCUIT Um : Voltage of electrode circuit
ENCLOSURE : Enclosure protection number
IM : User's Manual
WARNING
: Warning to apparatus
YOKOGAWA
TOKYO 180-8750 JAPAN :
Name and address of manufacturer
*1) The third figure from the last shows the last one
figure of the year of production. For example, the
year of production of the product engraved as
follows is year 1998.
No. F261GA091 813
↑
Produced in 1998
*2) The identification number of the notified body :
0344
*3) The product-producing country
12.2 FM
(1) Technical Data
• Explosionproof for Class I Division 1 Groups A, B,
C & D. Dust-ignitionproof for Class II/III Division 1
Groups E, F & G. Intrinsically safe (electrode) for
Class I Division 1 Groups A, B, C & D
Electrode circuit Vmax : 250V ac/dc
Temp. Class. T6
Enclosure : NEMA 4X
• Nonincendive for Class I, Division 2, Groups A, B,
C & D ; Suitable for Class II, Division 2, Groups F
& G ; Class III, Division 1 and 2
Intrinsically safe (electrode) for Class I Division 1
Groups A, B, C & D
Electrode Circuit Vmax : 250V ac/dc
Excitation Circuit : 130Vp 72/75Hz
Temp. Code : T5
Enclosure : NEMA 4X
(2) Installation
WARNING
• All wiring shall comply with national electrical
code ANSI/NFPA 70 and local electrical code.
• In hazardous locations, wiring to be in conduit
as shown in Figure 12.2.1.
(3) Operation
WARNING
• Open circuit before opening the covers and
seal all conduits with in 18 inches in hazardous
locations.
• Take care not to generate mechanical spark
when access to the instrument and peripheral
devices in hazardous locations.
(4) Maintenance and Repair
WARNING
The instrument modification or parts replacement
by other than authorized representative of
Yokogawa Electric Corporation is prohibited and
will void the approval of Factory Mutual Re-
search Corporation.
Conduit
Magnetic Flow Converter
Sealing Fitting
HAZARDOUS LOCATIONS
18" (457 mm) Max.
F0601.EPS
Figure 12.2.1 Conduit Wiring
Содержание AE100D
Страница 2: ......
Страница 333: ...Blank Page ...
Страница 395: ...Blank Page ...
Страница 401: ...Blank Page ...