10 Process Data Objects (PDO)
50
YASKAWA ELECTRIC
SIEP C730600 64A 1000-Series Option SI-ES3 Technical Manual
Accessed Drive Registers
Table 19
describes the accessed drive registers.
Table 19 Accessed Drive Registers
0x604C#1
0x00000001
32-bits
0x604C#2
0x00000001
32-bits
Reg.
Address
Internal Name/Short
Used in Context Evaluation
Description
Option Access
(RO/RW/WO)
0x003E
INVR_U102_OUTFREQ_RPM CoE: 0x6043 (vl velocity demand)
Output freq
[Unit: 1.0 r/min]
RO
0x00AC
INVR_U105_MSPEED_RPM
CoE: 0x6044 (vl velocity actual value)
Motor speed (U1-05)
[Unit: 1.0 r/min]
RO
0x0041
INVR_U102_OUTFREQ
CoE: 0x2110 (Output frequency)
Output freq (U1-02)
[Unit: o1-03]
RO
0x00FB
INVR_U103_OUTCUR2
CoE: 0x2120 (Output current)
Output current (U1-03)
RO
0x0048
INVR_U109_OUTTRQREF
CoE: 0x2130 (Output torque reference)
Torque reference (U1-09)
[Unit: 0.1%]
RO
0x0049
INVR_U110_TER_DIN
• CoE: 0x2180 (Free output default)
• CoE: 0x2270 (Drive DI input)
Input terminal status (U1-10)
RO
0x0044
INVR_U105_MSPEED
CoE: 0x2200 (Motor speed)
Motor speed (U1-05)
[Unit: o1-03]
RO
0x0046
INVR_U107_DCBUSVOLT
CoE: 0x2210 (DC bus voltage)
Bus voltage
[Unit: 1.0 V]
RO
0x004A
INVR_U111_TER_OUT
CoE: 0x60FD (Digital inputs)
Output terminal status
(U1-11)
RO
0x004E
INVR_U113_TER_A1IN
• CoE: 0x2190 (Free output default)
• CoE: 0x2220 (Analog input monitor A1)
A1 terminal level voltage
(U1-13)
RO
0x004F
INVR_U114_TER_A2IN
CoE: 0x2240 (Analog input monitor A2)
A2 terminal level voltage
(U1-14)
RO
0x0050
INVR_U114_TER_A3IN
CoE: 0x2260 (Analog input monitor A3)
A3 terminal level voltage
(U1-15)
RO
0x0080
INVR_U201_FAULTCUR
EtherCAT CoE Emergency services
Current fault (U2-01)
RO
0x0001
INVR_INVCTRL1
• CoE: 0x6040 (DSP402 controlword)
• CoE: 0x60FE (Digital outputs)
• CoE: 0x2000 (Operation command)
Run operation signal (option)
RW
0x0002
INVR_OPT_FREQ_REF
CoE: 0x2010 (Speed reference/Speed limit)
Frequency reference
RW
0x0004
INVR_OPT_TORQUE_REF
CoE: 0x2020 (Torque reference/Torque limit)
Torque reference/limit
[Unit: 0.1%]
RW
0x0005
INVR_OPT_TORQUE_COMP
CoE: 0x2030 (Torque compensation)
Torque compensation
[Unit: 0.1%]
RW
0x0007
INVR_OPT_FM_AOUT1
CoE: 0x20D0 (Analog output terminal FM
setting)
Analog output terminal FM
setting
RW
0x0008
INVR_OPT_AM_AOUT2
CoE: 0x20E0 (AM analog output)
AM analog output
RW
0x0009
INVR_OPT_MFUNC_DO
CoE: 0x20F0 (Multi-function DO output)
Multi function DO
RW
0x0200
INVR_C101_ACC1
CoE: 0x6048 (vl velocity acceleration)
Acceleration time 1 (C1-01)
[Unit: C1-10]
RW
0x0201
INVR_C102_DEC1
CoE: 0x6049 (vl velocity deceleration)
Deceleration time 1 (C1-02)
[Unit: C1-10]
RW
0x0208
INVR_C109_FASTSTOP
CoE: 0x604A (vl velocity quick stop)
Fast Stop time (C1-09)
[Unit: C1-10]
RW
0x0209
INVR_C110_ADTUNIT
• CoE: 0x6048 (vl velocity acceleration)
• CoE: 0x6049 (vl velocity deceleration)
• CoE: 0x604A (vl velocity quick stop)
Accel/Decel Time Setting
Units (C1-10)
RO
0x0289
INVR_D201_FREQUL
CoE: 0x6046#2 (vl velocity max amount)
Frequency Reference Upper
Limit (d2-01)
RW
0x028A
INVR_D202_FREQLL
CoE: 0x6046#1 (vl velocity min amount)
Frequency Reference Lower
Limit (d2-02)
RW