8 Object Dictionary
36
YASKAWA ELECTRIC
SIEP C730600 64A 1000-Series Option SI-ES3 Technical Manual
2120 (Hex) - Output Current
This object can be used to monitor the drive output current in units of Ampere. The current value resolution is the same
as in drive monitor U1-03 (for details refer to the technical manual of the drive).
2130 (Hex) - Output Torque Reference
This object can be used to monitor the output torque reference.
The availability of this object content depends on the drive control mode. If the selected control mode does not support
this monitor (equal to drive monitor U1-09), the torque reference monitor value will be 0. Refer to the drive technical
manual for details.
2140 (Hex) - MEMOBUS/Modbus Read Response
This object contains the data of the drive MEMOBUS/Modbus register specified in object 2040 (Hex). Bytes 1 and 2 of
subindex 1 will contain the data, and bytes 3 and 4 will contain the MEMOBUS/Modbus Address read.
Value: 0xAAAABBBB
0xAAAA = Drive register
0xBBBB = Data
2150 (Hex) - MEMOBUS/Modbus Write Response
This object contains the response from the drive when writing a drive parameter using a MEMOBUS/Modbus write
command (object 2050 (Hex)). Bytes 1 and 2 of subindex 1 will contain the data that were written, and bytes 3 and 4 will
contain the MEMOBUS/Modbus Address that was written to.
Value: 0xAAAABBBB
0xAAAA = Drive register
0xBBBB = Data
2155 (Hex) - PDO Parameter Write Response
Note:
Object only available in EtherCAT SAFEOP or Operational state. Object data is always cleared when a transition from PREOP to
SAFEOP is done.
Index
(Hex)
Subindex
Content
Default
Access
PDO
Mapping
Value Range
2120
–
Output current
–
Read Only
–
–
1
Value
–
Read Only
Tx
Unsigned 16
2
MEMOBUS/Modbus register address
00FB (Hex)
Read Only
No
Unsigned 16
Value (MEMOBUS/Modbus register): 0x00FB (Output current)
Index
(Hex)
Subindex
Content
Default
Access
PDO
Mapping
Value Range
2130
–
Output torque reference
–
Read Only
–
–
1
Value
–
Read Only
Tx
Unsigned 16
2
MEMOBUS/Modbus register address
0048 (Hex)
Read Only
No
Unsigned 16
Value (MEMOBUS/Modbus register): 0x0048 (Output torque reference)
Index (Hex)
Subindex
Content
Access
PDO Mapping
Value Range
2140
0
Number of entries
Read Only
No
Unsigned 8
Value: 0x01
1
MEMOBUS/Modbus read response
Read Only
Tx
Unsigned 32
Index (Hex)
Subindex
Content
Access
PDO Mapping
Value Range
2150
0
Number of entries
Read Only
No
Unsigned 8
Value: 0x01
1
MEMOBUS/Modbus write response
Read Only
Tx
Unsigned 32
Содержание SI-ES3