8 Object Dictionary
34
YASKAWA ELECTRIC
SIEP C730600 64A 1000-Series Option SI-ES3 Technical Manual
2080 to 3100 (Hex) - Freely Configurable Input Objects
The content of these objects can be freely selected by linking them to drive MEMOBUS/Modbus registers. Refer to
Selecting the Object Content on page 45
for details.
20D0 (Hex) - Analog Output Terminal FM Setting
This object controls the analog output terminal FM setting value.
20E0 (Hex) - AM Analog Output
This object controls the AM analog output value.
20F0 (Hex) - Multi-function DO Output
This object controls the multi-function DO outputs.
Index (Hex)
<1> Read/Write access when the option is in the Pre-Operational state. Read only access if the option is in the Operational state or if the drive is
running.
Subindex
Content
Default
Access
PDO
Mapping
Data Length
2080
0
Number of entries
2
Read Only
No
1 byte
1
Value
–
Read/Write
Possible
4 byte
Value of mapped MEMOBUS/Modbus register.
Value: 0xAAAABBBB
AAAA = MEMOBUS/Modbus register 1 value
BBBB = MEMOBUS/Modbus register 2 value
2
MEMOBUS/Modbus register address of
content 1 and 2
FFFF (Hex)/FFFF (Hex)
Read/
Write
<1>
No
4 byte
MEMOBUS/Modbus register addresses for content 1 and 2
Value: 0xAAAABBBB
AAAA = MEMOBUS/Modbus register 1 address
BBBB = MEMOBUS/Modbus register 2 address
Reg. value = 0xFFFF ' Mapping disabled.
Note:
Those values can only be changed in EtherCAT Pre-Operational state. Refer to
Table 4
for the state relations.
2090 to 20C0,
3000, and
3100
0
Number of entries
2
Read Only
No
1 byte
1
Value
–
Read/Write
Possible
2 byte
Value of mapped MEMOBUS/Modbus register.
Value: 0xAAAA
AAAA = MEMOBUS/Modbus register value
2
MEMOBUS/Modbus register address of
content
FFFF (Hex)
Read/
Write
<1>
No
2 byte
MEMOBUS/Modbus register addresses
Value: 0xAAAA
AAAA = MEMOBUS/Modbus register address.
Note:
Those values can only be changed in EtherCAT Pre-Operational state. Refer to
Table 4
for the state relations.
Index (Hex)
Subindex
Content
Access
PDO Mapping
Data Length
20D0
1
Value
Read/Write
Rx/Tx
–
2
MEMOBUS/Modbus register address
Read Only
No
–
Value (MEMOBUS/Modbus register): 0x0007 (Analog output terminal FM setting)
Index (Hex)
Subindex
Content
Access
PDO Mapping
Data Length
20E0
1
Value
Read/Write
Rx/Tx
–
2
MEMOBUS/Modbus register address
Read Only
No
–
Value (MEMOBUS/Modbus register): 0x0008 (AM analog output)
Index (Hex)
Subindex
Content
Access
PDO Mapping
Data Length
20F0
1
Value
Read/Write
Rx/Tx
–
2
MEMOBUS/Modbus register address
Read Only
No
–
Value (MEMOBUS/Modbus register): 0x0009 (Multi-function DO output)