4.3 CN1 Cables for I/O Signals
4-7
4.3 CN1 Cables for I/O Signals
4.3.1 Connector Type and Cable Size
Use the following connector and wire for CN1. The connector CN1 includes a set of case and a connector.
* Manufactured by Sumitomo 3M Ltd.
(1) Dimensional Drawings of Case
(2) Cable Size
Connector Type
Case
Connector
Type
Qty
Type
Qty
DE9411354
10326-52A0-008*
1 set
10126-3000VE*
(Soldered)
1
37.2 (1.46)
12.7 (0.50)
25.8 (1.02)
31.3 (1.23)
12.0 (0.47)
14.0 (0.55)
39.0 (1.54)
23.8 (0.94)
0.22
10.0 (0.39)
Units: mm (in)
Item
Specifications
Cable
Use twisted-pair or twisted-pair shielded wire.
Applicable wires
AWG24, 26, 28, 30
Cable Finished Diameter
φ
16 mm (0.63 in) max.