3 SERVOPACK Specifications and Dimensional Drawings
3-2
3.1 SERVOPACK Ratings and Specifications
SERVOPACK Model SGDS-
A5
01
02
04
08
10
15
20
30
Basic S
p
ecification
s
Max. Applicable Servomotor Capacity
[kW]
0.05
0.1
0.2
0.4
0.75
1.0
1.5
2.0
3.0
100 V
Continuous Output Current
[Arms]
0.66
0.91
2.1
2.8
−
−
−
−
−
Max. Output Current [Arms]
2.1
2.8
6.5
8.5
−
−
−
−
−
200 V
Continuous Output Current
[Arms]
0.66
0.91
2.1
2.8
5.5
7.6
10.7
16.7
23.8
Max. Output Current [Arms]
2.1
2.8
6.5
8.5
16.9
17.0
28
42
56
Input Power
Supply
SERVOPACK
Capacity Range
for 100/200 V
Single-phase 100 VAC
−
Single-phase 200 VAC
Single-
phase
200
VAC
−
−
−
Three-phase 200 VAC
200 V
Main Circuit
Three-phase (or single-phase) 200 to 230 VAC +10 to -15%, 50/60 Hz
Control Circuit
Single-phase 200 to 230 VAC +10 to -15%, 50/60 Hz
100 V
Main Circuit
Single-phase 100 to 115 VAC +10 to -15%, 50/60 Hz
Control Circuit
Single-phase 100 to 115 VAC +10 to -15%, 50/60 Hz
Control Method
Single or three-phase full-wave rectification IGBT-PWM (sine-wave driven)
Feedback
Serial encoder: 17-bit (incremental/absolute)
Operating
Conditions
Ambient/Storage
Temperature
0 to +55
°
C/ -20 to +85
°
C
Ambient/Storage
Humidity
90% RH or less (with no condensation)
Vibration/Shock
Resistance
4.9 m/s
2
/ 19.6 m/s
2
Configuration
Base-mounted (Rack mounting available as an option)
Performance
Speed Control Range
1:5000 (The lowest speed of the speed control range is the speed at
which the servomotor will not stop with a rated torque load.)
Speed
Regu-
lation
∗
Load
Regulation
0 to 100
%
load: 0.01
%
max. (at rated speed)
Voltage
Regulation
Rated voltage
±
10
%
: 0
%
(at rated speed)
Temperature
Regulation
25
±
25
°
C:
±
0.1
%
max. (at rated speed)
Frequency
Characteristics
600 Hz (at
J
L
=
J
M
)
Torque Control
Tolerance
(Repeatability)
±
1%
Soft Start Time Setting
0 to 10 s (Can be set individually for acceleration and deceleration.)
Содержание SGDS Sigma III Series
Страница 3: ...SGDS Sigma III Servo Amplifier User Manual for Mechatrolink II Communications...
Страница 21: ......
Страница 29: ...1 Outline 1 8 2 Connecting to SGMSH SGMGH Servomotors Power Supply Three phase 200VAC SGMGH Servomotor...
Страница 59: ...2 System Selection 2 5 4 Regenerative Resistors 2 28...
Страница 68: ...3 3 SERVOPACK Internal Block Diagrams 3 9 3 3 3 Three phase 200 V 1 0 kW...
Страница 82: ...3 7 Dimensional Drawings of Base mounted SERVOPACK Model SGDS 12A 12A 3 23 Three phase 1 5kW...
Страница 133: ...5 Wiring 5 7 2 Connecting Externally Regenerative Resistors 5 28...
Страница 229: ...7 Operation 7 7 4 Absolute Encoder Home Position Offset 7 38...
Страница 375: ...Sigma II User s Manual Index Index 8...