7 Operation
7.3.3 Software Limit Settings
7-12
(2) Software Limit Check using References
Enable or disable software limit checks when target position references such as POSING or INTERPOLATE are
input. When the input target position exceeds the software limit, a deceleration stop will be performed from the
software limit set position.
(3) Software Limit Setting
Set software limits in the positive and negative directions.
Because the limit zone is set according to the (+) or (-) direction, the negative (
-
) limit must be less than the
positive (+) limit.
The negative limit must be less than the positive limit.
Parameter
Description
Pn801
n.
0
No software limit check using references. (Factory setting)
n.
1
Software limit check using references.
Pn804
Pn805
Forward Software Limit
Setting Range
Setting Unit
Factory Setting
Setting Validation
-1073741823 to 1073741823
1 Reference Unit
8192
∗
99999
Immediately
Pn806
Pn807
Reverse Software Limit
Setting Range
Setting Unit
Factory Setting
Setting Validation
-1073741823 to 1073741823
1 Reference Unit
8192
∗
99999
Immediately
Position
Position
Содержание SGDS Sigma III Series
Страница 3: ...SGDS Sigma III Servo Amplifier User Manual for Mechatrolink II Communications...
Страница 21: ......
Страница 29: ...1 Outline 1 8 2 Connecting to SGMSH SGMGH Servomotors Power Supply Three phase 200VAC SGMGH Servomotor...
Страница 59: ...2 System Selection 2 5 4 Regenerative Resistors 2 28...
Страница 68: ...3 3 SERVOPACK Internal Block Diagrams 3 9 3 3 3 Three phase 200 V 1 0 kW...
Страница 82: ...3 7 Dimensional Drawings of Base mounted SERVOPACK Model SGDS 12A 12A 3 23 Three phase 1 5kW...
Страница 133: ...5 Wiring 5 7 2 Connecting Externally Regenerative Resistors 5 28...
Страница 229: ...7 Operation 7 7 4 Absolute Encoder Home Position Offset 7 38...
Страница 375: ...Sigma II User s Manual Index Index 8...