11.4 Parameter Recording Table
11-47
Pn136
0 ms
Gain Switching Waiting Time 2
Pn139
0000
Automatic Gain Changeover Related
Switch 1
∆
Pn144
100.0 %
Reference Filter Bias (Reverse)
Pn150
0210
Predictive Control Selection Switch
∆
Pn151
100 %
Predictive Control Acceleration/
Deceleration Gain
Pn152
100 %
Predictive Control Weighting Ratio
Pn1A0
60 %
Servo Rigidity
Pn1A1
60 %
Servo Rigidity #2
Pn1A2
0.72 ms
Speed Feedback Filter Time Constant
Pn1A3
0.72 ms
Speed Feedback Filter Time Constant #2
Pn1A4
0.36 ms
Torque Reference Filter Time Constant
Pn1A7
1121
Utility Control Switch
Pn1A9
37 Hz
Utility Integral Gain
Pn1AA
60 Hz
Position Proportional Gain
Pn1AB
0 Hz
Speed Integral Gain
Pn1AC
120 Hz
Speed Proportional Gain
Pn200
0100
Position Control Reference Form
Selection Switch
∆
Pn205
65535 Rev
Multi-turn Limit Setting
∆
Pn207
0010
Position Reference Function Switch
∆
Pn209
−
Reserved (Do not change)
−
Pn20A
32768
pitches/Rev
Number of External Scale Pitch
∆
Pn20E
4
Electronic Gear Ratio (Numerator)
∆
Pn210
1
Electronic Gear Ratio
(Denominator)
∆
Pn212
2048 P/Rev
PG Dividing Pulse (pulse input)
∆
Pn214
0
Backlash Compensation Amount
Pn215
0.00ms
Backlash Compensation Time
Constant
Pn216
−
Reserved (Do not change)
−
Pn217
−
Reserved (Do not change)
−
Pn280
0
µ
m
Linear Scale Pitch
∆
Pn281
20 P/ (4 multi-
ple pitches)
Encoder Output Resolution
∆
Pn300
−
Reserved (Do not change)
−
Pn301
−
Reserved (Do not change)
−
Pn302
−
Reserved (Do not change)
−
Pn303
−
Reserved (Do not change)
−
Pn304
500 RPM
JOG Speed
Pn305
0 ms
Soft Start Acceleration Time
Pn306
0 ms
Soft Start Deceleration Time
Pn307
−
Reserved (Do not change)
−
Pn308
0.00 ms
Speed Feedback Filter Time
Constant
Pn310
0000
Vibration Detection Switch
Pn311
100 %
Vibration Detection Sensibility
Pn312
50 RPM
Vibration Detection Level
Pn400
−
Reserved (Do not change)
−
parameter
No.
Factory
Setting
Name
Changing
Method
Содержание SGDS Sigma III Series
Страница 3: ...SGDS Sigma III Servo Amplifier User Manual for Mechatrolink II Communications...
Страница 21: ......
Страница 29: ...1 Outline 1 8 2 Connecting to SGMSH SGMGH Servomotors Power Supply Three phase 200VAC SGMGH Servomotor...
Страница 59: ...2 System Selection 2 5 4 Regenerative Resistors 2 28...
Страница 68: ...3 3 SERVOPACK Internal Block Diagrams 3 9 3 3 3 Three phase 200 V 1 0 kW...
Страница 82: ...3 7 Dimensional Drawings of Base mounted SERVOPACK Model SGDS 12A 12A 3 23 Three phase 1 5kW...
Страница 133: ...5 Wiring 5 7 2 Connecting Externally Regenerative Resistors 5 28...
Страница 229: ...7 Operation 7 7 4 Absolute Encoder Home Position Offset 7 38...
Страница 375: ...Sigma II User s Manual Index Index 8...