4.1 SERVOPACK Main Circuit Wire Size
4-3
(4) Three-phase for 200 V
Note: 1. Wire sizes were selected for three cables per bundle at 40
°
C ambient temperature with the rated
current.
2. Use cable with withstand voltage of 600 V for main circuits.
3. If cables are bundled in PVC or metal ducts, consider the reduction ratio of the allowable current.
4. Use heat-resistant cable under high ambient or panel temperatures where normal vinyl cable will
rapidly deteriorate.
5. Use cable within the allowable moment of inertia.
6. Do not use in continuous regenerating status.
External Terminal Name
Terminal
Symbol
SERVOPACK Model
SGDS-
10AE
1.5AE
2.0AE
3.0AE
Main circuit power input terminals
L1, L2, L3
HIV2.0
Servomotor connection terminals
U, V, W
HIV2.0
Control power input terminals
L1C, L2C
HIV1.25
External regenerative resistor connection terminals
B1/
, B2
HIV2.0
Ground terminal
HIV2.0 min.
Содержание SGDS Sigma III Series
Страница 3: ...SGDS Sigma III Servo Amplifier User Manual for Mechatrolink II Communications...
Страница 21: ......
Страница 29: ...1 Outline 1 8 2 Connecting to SGMSH SGMGH Servomotors Power Supply Three phase 200VAC SGMGH Servomotor...
Страница 59: ...2 System Selection 2 5 4 Regenerative Resistors 2 28...
Страница 68: ...3 3 SERVOPACK Internal Block Diagrams 3 9 3 3 3 Three phase 200 V 1 0 kW...
Страница 82: ...3 7 Dimensional Drawings of Base mounted SERVOPACK Model SGDS 12A 12A 3 23 Three phase 1 5kW...
Страница 133: ...5 Wiring 5 7 2 Connecting Externally Regenerative Resistors 5 28...
Страница 229: ...7 Operation 7 7 4 Absolute Encoder Home Position Offset 7 38...
Страница 375: ...Sigma II User s Manual Index Index 8...