11 Appendix
11.2.2 List of Parameters
11-24
Pn408
Torque Related Function Switch
2
−
−
0000
∆/
8.6.9
Pn409
1st Step Notch Filter Frequency
2
50 to 2000 Hz
1 Hz
2000 Hz
8.6.9
Pn40A
1st Step Notch Filter Q Value
2
0.50 to 10.00
0.01
0.70
Pn40C
2nd Step Notch Filter Frequency
2
50 to 2000 Hz
1 Hz
2000 Hz
Pn40D
2nd Step Notch Filter Q Value
2
0.50 to 10.00
0.01
0.70
Pn40F
2nd Step 2nd Torque Reference
Filter Frequency
2
100 to 2000 Hz
1 Hz
2000 Hz
Pn410
2nd Step 2nd Torque Reference
Filter Q Value
2
0.50 to 10.00
0.01
0.70
Pn411
3rd Step Torque Reference Filter
Time Constant
2
0 to 65535
µ
s
1 µ
s
0
µ
s
Pn412
1st Step 2nd Torque Reference
Filter Time Constant
2
0.00 to 655.35 ms
0.01 ms
1.00 ms
8.6.6
Pn413
1st Step 3rd Torque Reference
Filter Time Constant
2
0.00 to 655.35 ms
0.01 ms
1.00 ms
Pn414
1st Step 4th Torque Reference
Filter Time Constant
2
0.00 to 655.35 ms
0.01 ms
1.00 ms
Pn420
Damping for Vibration
Suppression on Stopping
2
10 to 100%
1%
100%
8.6.10
Pn421
Vibration Suppression Starting
Time
2
0 to 65535 ms
1 ms
1000 ms
Pn422
Gravity Compensation Torque
2
-200.00 to 200.00%
0.01 %
0.00%
−
Pn456
Sweep Torque Reference
Amplitude
2
1 to 800%
1%
15%
−
Pn501
Zero Clamp Level
2
0 to 10000 RPM
1 RPM
10 RPM
−
Pn502
Zero Speed Level
2
1 to 10000 RPM
1 RPM
20 RPM
−
Note:
: Can be changed at any time, and immediately validated after changing. (Called an online
parameter.)
∆
: Validated after a Set Up Device command is sent, when loading and using parameters at
power ON. Also validated when turning OFF and then ON the power supply again after a
Write Non-volatile Parameter (PPRM_WR) command is sent.
Parameter
No.
Name
Data
Size
Setting Range
Unit
Factory
Setting
Changing
Method
Reference
Section
0
1
0
1
N/A
Uses
1st step
notch filter for torque reference.
Uses the smaller value between
motor max. speed
or parameter Pn407 as
speed limit value.
Uses the smaller value between
overspeed detection speed
or parameter
Pn407 as speed limit value.
1st Step Notch Filter Selection
(Refer to "8.6.9 Torque Reference Filter.")
0
1
2nd step
notch filter N/A
Uses
2nd step
notch filter for torque reference.
2nd Step Notch Filter Selection
(Refer to "8.6.9 Torque Reference Filter.")
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
Speed Limit Selection
Reserved (Do not change)
∆
Changing Method
Changing Method
Changing Method
Содержание SGDS Sigma III Series
Страница 3: ...SGDS Sigma III Servo Amplifier User Manual for Mechatrolink II Communications...
Страница 21: ......
Страница 29: ...1 Outline 1 8 2 Connecting to SGMSH SGMGH Servomotors Power Supply Three phase 200VAC SGMGH Servomotor...
Страница 59: ...2 System Selection 2 5 4 Regenerative Resistors 2 28...
Страница 68: ...3 3 SERVOPACK Internal Block Diagrams 3 9 3 3 3 Three phase 200 V 1 0 kW...
Страница 82: ...3 7 Dimensional Drawings of Base mounted SERVOPACK Model SGDS 12A 12A 3 23 Three phase 1 5kW...
Страница 133: ...5 Wiring 5 7 2 Connecting Externally Regenerative Resistors 5 28...
Страница 229: ...7 Operation 7 7 4 Absolute Encoder Home Position Offset 7 38...
Страница 375: ...Sigma II User s Manual Index Index 8...