8 Adjustments
8.6.6 Switching Gain Settings
8-34
(9) Less Deviation Control Related Parameters
Pn1A0
Servo Rigidity
Setting Range
Setting Unit
Factory Setting
Setting Validation
1% to 500%
1%
60%
Immediately
Pn1A1
Servo Rigidity 2
Setting Range
Setting Unit
Factory Setting
Setting Validation
1% to 500%
1%
60%
Immediately
Pn1A2
Speed Feedback Filter Time Constant
Setting Range
Setting Unit
Factory Setting
Setting Validation
0.30 to 32.00 ms
0.01 ms
0.72 ms
Immediately
Pn1A3
Speed Feedback Filter Time Constant #2
Setting Range
Setting Unit
Factory Setting
Setting Validation
0.30 to 32.00 ms
0.01 ms
0.72 ms
Immediately
Pn1A7
Auxiliary Control Switches
Setting Range
Setting Unit
Factory Setting
Setting Validation
−
−
1121
Immediately
Speed
Position
Speed
Position
Speed
Position
Speed
Position
Speed
Position
Parameter
Function
Pn1A7
n.
0
Do not perform integral compensation processing.
n.
1
Perform integral compensation processing. (Factory setting)
n.
2
Use gain switching without position error.
Perform integral compensation on Gain Settings 1.
Do not perform integral compensation on Gain Settings 2.
n.
3
Use gain switching without position error.
Do not perform integral compensation on Gain Settings 1.
Perform integral compensation on Gain Settings 2.
Содержание SGDS Sigma III Series
Страница 3: ...SGDS Sigma III Servo Amplifier User Manual for Mechatrolink II Communications...
Страница 21: ......
Страница 29: ...1 Outline 1 8 2 Connecting to SGMSH SGMGH Servomotors Power Supply Three phase 200VAC SGMGH Servomotor...
Страница 59: ...2 System Selection 2 5 4 Regenerative Resistors 2 28...
Страница 68: ...3 3 SERVOPACK Internal Block Diagrams 3 9 3 3 3 Three phase 200 V 1 0 kW...
Страница 82: ...3 7 Dimensional Drawings of Base mounted SERVOPACK Model SGDS 12A 12A 3 23 Three phase 1 5kW...
Страница 133: ...5 Wiring 5 7 2 Connecting Externally Regenerative Resistors 5 28...
Страница 229: ...7 Operation 7 7 4 Absolute Encoder Home Position Offset 7 38...
Страница 375: ...Sigma II User s Manual Index Index 8...