8.6 Servo Gain Adjustment Functions
8-49
8.6.11 Backlash Compensation
(1) Pn207= 1
The Backlash Compensation Amount (Pn214) is added to forward reference.
(2) Pn207= 2
The Backlash Compensation Amount (Pn214) is added to reverse reference.
8.6.12 Position Integral
Pn214
Backlash Compensation Amount
Setting Range
Setting Unit
Factory Setting
Setting Validation
-32767 to 32767
reference units
Reference unit
0 reference units
Immediately
Pn215
Backlash Compensation Time Constant
Setting Range
Setting Unit
Factory Setting
Setting Validation
0.00 to 655.35 ms
0.01 ms
0.00 ms
Immediately
Position
Position
Parameter
Meaning
Pn207
n.
0
Disabled. (Factory Setting)
n.
1
Compensate in forward direction.
n.
2
Compensate in reverse direction.
Pn214
Pn214
Machine
Motor shaft
Forward direction
Machine
Motor axis
Pn214
Pn214
Machine
Motor shaft
Reverse direction
Machine
Motor axis
Pn11F
Position Integral
Setting Range
Setting Unit
Factory Setting
Setting Validation
0.0 to 5000.0 ms
0.1 ms
0.0 ms
Immediately
This function adds an integral control operation to the position loop. It is effective for electronic cam or electronic shaft
applications. Refer to the application examples in the user’s manual for the MP9
or MP2
Controllers from
Yaskawa for details.
Position
Содержание SGDS Sigma III Series
Страница 3: ...SGDS Sigma III Servo Amplifier User Manual for Mechatrolink II Communications...
Страница 21: ......
Страница 29: ...1 Outline 1 8 2 Connecting to SGMSH SGMGH Servomotors Power Supply Three phase 200VAC SGMGH Servomotor...
Страница 59: ...2 System Selection 2 5 4 Regenerative Resistors 2 28...
Страница 68: ...3 3 SERVOPACK Internal Block Diagrams 3 9 3 3 3 Three phase 200 V 1 0 kW...
Страница 82: ...3 7 Dimensional Drawings of Base mounted SERVOPACK Model SGDS 12A 12A 3 23 Three phase 1 5kW...
Страница 133: ...5 Wiring 5 7 2 Connecting Externally Regenerative Resistors 5 28...
Страница 229: ...7 Operation 7 7 4 Absolute Encoder Home Position Offset 7 38...
Страница 375: ...Sigma II User s Manual Index Index 8...