11.2 List of Parameters
11-21
Pn1A7
Utility Control Switch
2
−
−
1121
∆
8.6.6
8.6.8
Pn1A9
Utility Integral Gain
2
0 to 500 Hz
1 Hz
60 Hz
8.6.8
Pn1AA
Position Proportional Gain
2
0 to 500 Hz
1 Hz
60 Hz
Pn1AB
Speed Integral Gain
2
0 to 500 Hz
1 Hz
60 Hz
Pn1AC
Speed Proportional Gain
2
0 to 2000 Hz
1 Hz
380 Hz
Pn200
Position Control Reference Form
Selection Switch
2
−
−
0100
∆
−
Pn205
Multi-turn Limit Setting *
2
0 to 65535 rev
rev
65535 rev
∆
7.7.3
Note:
: Can be changed at any time, and immediately validated after changing. (Called an online
parameter.)
∆
: Validated after a Set Up Device command is sent, when loading and using parameters at
power ON. Also validated when turning OFF and then ON the power supply again after a
Write Non-volatile Parameter (PPRM_WR) command is sent.
Parameter
No.
Name
Data
Size
Setting Range
Unit
Factory
Setting
Changing
Method
Reference
Section
0
1
2
3
0
1
2
0
1
n.
4th
digit
3rd
digit
2nd
digit
1st
digit
Do not perform integral compensation processing.
Perform integral compensation processing. (Factory setting)
Use gain switching for less deviation. Perform integral compensation on Gain Settings 1.
Do not perform integral compensation on Gain Settings 2.
Use gain switching for less deviation. Do not perform integral compensation on Gain
Settings 1. Perform integral compensation on Gain Setting 2.
Reserved (Do not change)
Set the unit speed feedback filter time constant to 0.1 ms.
Set the unit speed feedback filter time constant to 0.01 ms.
Use the fullclosed feedback compensation.
Use feedback compensation.
Integral Compensation processing
(Refer to "8.6.6 Switching Gain Settings, 8.6.8 Less Deviation Control.")
Feedback compensation selection
Set units of filter setting
Reserved (Do not change)
Reserved (Do not change)
Reserved (Do not change)
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
Reserved (Do not change)
Reserved (Do not change)
Содержание SGDS Sigma III Series
Страница 3: ...SGDS Sigma III Servo Amplifier User Manual for Mechatrolink II Communications...
Страница 21: ......
Страница 29: ...1 Outline 1 8 2 Connecting to SGMSH SGMGH Servomotors Power Supply Three phase 200VAC SGMGH Servomotor...
Страница 59: ...2 System Selection 2 5 4 Regenerative Resistors 2 28...
Страница 68: ...3 3 SERVOPACK Internal Block Diagrams 3 9 3 3 3 Three phase 200 V 1 0 kW...
Страница 82: ...3 7 Dimensional Drawings of Base mounted SERVOPACK Model SGDS 12A 12A 3 23 Three phase 1 5kW...
Страница 133: ...5 Wiring 5 7 2 Connecting Externally Regenerative Resistors 5 28...
Страница 229: ...7 Operation 7 7 4 Absolute Encoder Home Position Offset 7 38...
Страница 375: ...Sigma II User s Manual Index Index 8...