11.2 List of Parameters
11-33
Pn802
Reserved (Do not change)
−
−
−
−
−
−
Pn803
Origin Range
2
0 to 250
Reference
unit
10
7.4.4
Pn804
Pn805
Forward Software Limit
4
-1073741823 to
1073741823
Reference
unit
8192
∗
999
99
7.3.3
Pn806
Pn807
Reverse Software Limit
4
-1073741823 to
1073741823
Reference
unit
−
8192
∗
99999
Pn808
Pn809
Absolute Encoder Origin Offset*
4
-1073741823 to
1073741823
Reference
unit
0
7.7.4
Pn80A
1st Step Linear Acceleration
Constant
2
1 to 65535
10000
reference
units/s
2
100
6.3.28
6.3.29
7.4.3
Pn80B
2nd Step Linear Acceleration
Constant
2
1 to 65535
10000
reference
units/s
2
100
Pn80C
Acceleration Constant Switching
Speed
2
0 to 65535
100
reference
units/s
0
Pn80D
1st Step Linear Deceleration
Constant
2
1 to 65535
10000
reference
units/s
2
100
Pn80E
2nd Step Linear Deceleration
Constant
2
1 to 65535
10000
reference
units/s
2
100
Pn80F
Deceleration Constant Switching
Speed
2
0 to 65535
100
reference
units/s
0
Pn810
Exponential Function Accel/
Decel Bias
2
0 to 32767
Reference
unit/s
0
7.4.3
Pn811
Exponential Function Accel/
Decel Time Constant
2
0 to 5100
0.1 ms
0
Pn812
Moving Average Time
2
0 to 5100
0.1 ms
0
Pn813
Reserved (Do not change)
−
−
−
−
−
−
Pn814
Pn815
Final Travel Distance for External
Input Positioning (EX_POSING)
4
-1073741823 to
1073741823
Reference
unit
100
6.3.28
7.4.4
* Enabled when setting is made before SENS_ON, not after SENS_ON.
Note:
: Can be changed at any time, and immediately validated after changing. (Called an online
parameter.)
: Can be changed when DEN=1. Immediately validated after changing. Do not change when
DEN = 0. Doing so may lead to overrun. (Called an offline parameter.)
Parameter
No.
Name
Data
Size
Setting Range
Unit
Factory
Setting
Changing
Method
Reference
Section
Содержание SGDS Sigma III Series
Страница 3: ...SGDS Sigma III Servo Amplifier User Manual for Mechatrolink II Communications...
Страница 21: ......
Страница 29: ...1 Outline 1 8 2 Connecting to SGMSH SGMGH Servomotors Power Supply Three phase 200VAC SGMGH Servomotor...
Страница 59: ...2 System Selection 2 5 4 Regenerative Resistors 2 28...
Страница 68: ...3 3 SERVOPACK Internal Block Diagrams 3 9 3 3 3 Three phase 200 V 1 0 kW...
Страница 82: ...3 7 Dimensional Drawings of Base mounted SERVOPACK Model SGDS 12A 12A 3 23 Three phase 1 5kW...
Страница 133: ...5 Wiring 5 7 2 Connecting Externally Regenerative Resistors 5 28...
Страница 229: ...7 Operation 7 7 4 Absolute Encoder Home Position Offset 7 38...
Страница 375: ...Sigma II User s Manual Index Index 8...