6.3.31 Torque Control (TRQCTRL: 3DH)
• Related Parameters
• Speed Reference Option Operation
Byte
TRQCTRL
Description
Command
Response
1
3DH
3DH
Processing
classifications
Motion command
group
Synchronization
classifications
Asynchronous
2
ALARM
Processing time
Within communi-
cations cycle
Subcommand
Can be used
3
OPTION
STATUS
• The Servo does not perform position control and speed control, but directly
performs torque control.
• Can be used during phases 2 and 3.
• A command warning will occur and the command will be ignored in the
following cases.
- During phases other than phases 2 and 3: Command warning 1 (A.95A)
• OPTION field can be used. Refer to
6.5.2 Option Field Specifications:
OPTION
for details.
• TOREF
TOREF is a torque reference and has signed 4 bytes of data. The unit for
torque reference is [maximum motor torque/40000000H]. The direction is
specified by the sign.
When the designation for TOREF is larger, it is clamped at the maximum
torque.
• During execution of this command, the following bits of STATUS are
allocated.
D11: V_LIM (speed limit bit)
0: Speed limit not detected
1: Speed limit detected
• MONITOR1, 2, 3, 4 (monitor)
The unit for torque is [maximum motor torque/40000000H].
• Setting the speed reference option (VLIM)
Setting range: 0 to 40000000H (maximum motor speed/40000000H)
Refer to
on
page 6-39
.
4
5
VLIM
MONITOR1
6
7
8
9
TQREF
MONITOR2
10
11
12
13
SEL_MON 1/2
SEL_MON 1/2
14
IO_MON
15
16
WDT
RWDT
17
For
subcommands
use. Refer to
6.4
Subcommands
.
For
subcommands
use. Refer to
6.4
Subcommands
.
18
19
20
21
22
23
24
25
26
27
28
29
Pn No.
Description
Pn407
Speed Limit at Torque Control
Parameter
Description
Pn002
n.
0
VLIM is not available.
Set VLIM to 0.
n.
1
VLIM operates as the speed limit value.
Содержание SGDS Sigma III Series
Страница 3: ...SGDS Sigma III Servo Amplifier User Manual for Mechatrolink II Communications...
Страница 21: ......
Страница 29: ...1 Outline 1 8 2 Connecting to SGMSH SGMGH Servomotors Power Supply Three phase 200VAC SGMGH Servomotor...
Страница 59: ...2 System Selection 2 5 4 Regenerative Resistors 2 28...
Страница 68: ...3 3 SERVOPACK Internal Block Diagrams 3 9 3 3 3 Three phase 200 V 1 0 kW...
Страница 82: ...3 7 Dimensional Drawings of Base mounted SERVOPACK Model SGDS 12A 12A 3 23 Three phase 1 5kW...
Страница 133: ...5 Wiring 5 7 2 Connecting Externally Regenerative Resistors 5 28...
Страница 229: ...7 Operation 7 7 4 Absolute Encoder Home Position Offset 7 38...
Страница 375: ...Sigma II User s Manual Index Index 8...