286
YASKAWA
TOEPYAIGA5002A GA500 Programming
■
F7-72: PZD3 Read
No.
(Hex.)
Name
Description
Default
(Range)
F7-72
(078C)
PZD3 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD3 (PPO input). A
value of 0 will disable the PZD3 (PPO input) load operation from the MEMOBUS/Modbus register.
0
■
F7-73: PZD4 Read
No.
(Hex.)
Name
Description
Default
(Range)
F7-73
(078D)
PZD4 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD4 (PPO input). A
value of 0 will disable the PZD4 (PPO input) load operation from the MEMOBUS/Modbus register.
0
■
F7-74: PZD5 Read
No.
(Hex.)
Name
Description
Default
(Range)
F7-74
(078E)
PZD5 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD5 (PPO input). A
value of 0 will disable the PZD5 (PPO input) load operation from the MEMOBUS/Modbus register.
0
■
F7-75: PZD6 Read
No.
(Hex.)
Name
Description
Default
(Range)
F7-75
(078F)
PZD6 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD6 (PPO input). A
value of 0 will disable the PZD6 (PPO input) load operation from the MEMOBUS/Modbus register.
0
■
F7-76: PZD7 Read
No.
(Hex.)
Name
Description
Default
(Range)
F7-76
(0790)
PZD7 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD7 (PPO input). A
value of 0 will disable the PZD7 (PPO input) load operation from the MEMOBUS/Modbus register.
0
■
F7-77: PZD8 Read
No.
(Hex.)
Name
Description
Default
(Range)
F7-77
(0791)
PZD8 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD8 (PPO input). A
value of 0 will disable the PZD8 (PPO input) load operation from the MEMOBUS/Modbus register.
0
■
F7-78: PZD9 Read
No.
(Hex.)
Name
Description
Default
(Range)
F7-78
(0792)
PZD9 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD9 (PPO input). A
value of 0 will disable the PZD9 (PPO input) load operation from the MEMOBUS/Modbus register.
0
■
F7-79: PZD10 Read
No.
(Hex.)
Name
Description
Default
(Range)
F7-79
(0793)
PZD10 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD10 (PPO input). A
value of 0 will disable the PZD10 (PPO input) load operation from the MEMOBUS/Modbus register.
0
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание GA500 series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 456: ...2 12 T Auto Tuning 456 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 488: ...3 8 Test Run Checklist 488 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 494: ...4 3 Remove and Reattach the Keypad 494 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 514: ...5 6 Connect the Drive to a PC 514 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 525: ...YASKAWA TOEPYAIGA5002A GA500 Programming 525...