YASKAWA
TOEPYAIGA5002A GA500 Programming
161
The drive ramps the motor to stop as specified by the deceleration time. The default setting for the deceleration time
is
C1-02 [Deceleration Time 1]
. The actual deceleration time changes as the load conditions change (for example,
mechanical loss and inertia).
If the output frequency is less than or equal to the value set in
b2-01 [DC Injection/Zero SpeedThreshold]
during
deceleration, the drive will do DC Injection Braking, Zero Speed Control, or Short Circuit Braking, as specified by
the control method.
•
Ramp to Stop with V/f Control and OLV Control Methods
Parameter
b2-01
sets the frequency to start DC Injection Braking at stop. If the output frequency is less than or
equal to the value set in
b2-01
during deceleration, then the drive will perform DC Injection Braking for the time set
in
b2-04 [DC Inject Braking Time at Stop]
.
Figure 2.9 Ramp to Stop with V/f and OLV Control Methods
Note:
When
b2-01 ≤ E1-09 [Minimum Output Frequency]
, the drive will start DC Injection Braking from the frequency set in
E1-09
.
•
Ramp to Stop with OLV/PM, AOLV/PM, and EZOLV Control Methods
Parameter
b2-01
sets the frequency to start Short Circuit Braking. When the output frequency is less than or equal
to the value set in
b2-01
during deceleration, then the drive will do Short Circuit Braking for the time set in
b2-13
[Short Circuit Brake Time @ Stop]
. When
b2-04 ≠ 0
, the drive will do DC Injection Braking for the time set in
b2-
04
when Short Circuit Braking is complete.
Figure 2.10 Ramp to Stop with OLV/PM, AOLV/PM, and EZOLV Control Methods
Note:
When
b2-01 ≤ E1-09
, the drive will start Short Circuit Braking from the frequency set in
E1-09
.
If
b2-01 = 0 Hz
and
E1-09 = 0 Hz
, the drive will not do Short Circuit Braking.
1 : Coast to Stop
When you enter the Stop command or turn OFF the Run command, the drive turns OFF the output and coasts the
motor to stop.
Load conditions will have an effect on the deceleration rate as the motor coasts to stop (for example, mechanical loss
and inertia).
Содержание GA500 series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 456: ...2 12 T Auto Tuning 456 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 488: ...3 8 Test Run Checklist 488 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 494: ...4 3 Remove and Reattach the Keypad 494 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 514: ...5 6 Connect the Drive to a PC 514 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 525: ...YASKAWA TOEPYAIGA5002A GA500 Programming 525...