1.21 Defaults by Drive Model and Duty Rating ND/HD
YASKAWA
TOEPYAIGA5002A GA500 Programming
121
No.
Name
Unit
Default
-
Drive Model
-
2042
2056
2070
2082
C6-01
Normal /
Heavy Duty
Selection
-
HD
ND
HD
ND
HD
ND
HD
ND
0
1
0
1
0
1
0
1
o2-04
Drive Model
(KVA)
Selection
Hex.
6B
6D
6E
6F
E2-11
(E4-11, E5-
02)
Motor Rated
Power
kW
7.5
11
11
15
15
18.5
18.5
22
L3-24
Motor Accel
Time @ Rated
Torque
s
0.175
0.265
0.265
0.244
0.244
0.317
0.317
0.355
L8-02
Overheat
Alarm Level
°C
115
115
125
125
120
120
135
135
L8-09
Output Ground
Fault
Detection
-
1
1
1
1
1
1
1
1
n1-03
Hunting
Prevention
Time Constant
ms
10
10
10
10
10
10
10
10
n3-02
HSB Current
Limit Level
1
150
120
150
120
150
120
150
120
n5-02
Motor Inertia
Acceleration
Time
s
0.175
0.265
0.265
0.244
0.244
0.317
0.317
0.355
*1
Parameters within parentheses are for motor 2.
◆
Three-Phase 400 V Class
Name
Unit
Default
-
Drive Model
-
4001
4002
4004
4005
C6-01
Normal /
Heavy Duty
Selection
-
HD
ND
HD
ND
HD
ND
HD
ND
0
1
0
1
0
1
0
1
o2-04
Drive Model
(KVA)
Selection
Hex.
91
92
93
94
E2-11
(E4-11, E5-
02)
Motor Rated
Power
kW
0.2
0.4
0.4
0.75
0.75
1.5
1.5
2.2
b3-04
V/f Gain
during Speed
Search
%
100
100
100
100
100
100
100
100
b3-06
Speed
Estimation
Current Level
1
-
1.0
1.0
0.5
0.5
0.5
0.5
0.5
0.5
b3-08
Speed
Estimation
ACR P Gain
-
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
b3-26
Direction
Determination
Level
-
1000
1000
1000
1000
1000
1000
1000
1000
b8-03
Energy Saving
Filter Time
s
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
b8-04
Energy Saving
Coefficient
Value
-
713.8
576.4
576.4
447.4
447.4
338.8
338.8
313.6
C6-02
Carrier
Frequency
Selection
-
3
7
3
7
3
7
3
7
E2-01
(E4-01)
Motor Rated
Current (FLA)
A
0.6
1
1
1.6
1.6
3.1
3.1
4.2
Содержание GA500 series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 456: ...2 12 T Auto Tuning 456 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 488: ...3 8 Test Run Checklist 488 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 494: ...4 3 Remove and Reattach the Keypad 494 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 514: ...5 6 Connect the Drive to a PC 514 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 525: ...YASKAWA TOEPYAIGA5002A GA500 Programming 525...