196
YASKAWA
TOEPYAIGA5002A GA500 Programming
■
b5-62: PID Trim Mode Lower Limit Value
No.
(Hex.)
Name
Description
Default
(Range)
b5-62
(119B)
PID Trim Mode Lower Limit
Value
Sets the PID Trim Mode Lower Limit Value as a percentage of the maximum output frequency.
0.00%
(0.00 - 100.00%)
Note:
Set
b5-01 = 3, 4, 7, or 8
to enable this parameter.
■
b5-63: PID Differential FB Monitor Sel
No.
(Hex.)
Name
Description
Default
(Range)
b5-63
(119C)
PID Differential FB Monitor
Sel
Selects the monitor (
Ux-xx
) used as the PID Differential Feedback. Set the
x-xx
part of the
Ux-xx
[Monitor]
.
000
(000 - 999)
Note:
•
You cannot select
parameter U5-xx
.
•
This parameter is disabled when set to
000
.
■
b5-64: PID Differential FB Monitor Gain
No.
(Hex.)
Name
Description
Default
(Range)
b5-64
(119D)
PID Differential FB Monitor
Gain
Sets the gain for the monitor specified in
b5-63 [PID Differential FB Monitor Sel]
.
1.00
(0.00 - 10.00)
■
b5-65: PID Differential FB Monitor Bias
No.
(Hex.)
Name
Description
Default
(Range)
b5-65
(119F)
PID Differential FB Monitor
Bias
Sets the bias for the monitor specified in
b5-63 [PID Differential FB Monitor Sel]
.
0.00
(-10.00 - +10.00)
■
b5-66: PID Feedback Monitor Level
No.
(Hex.)
Name
Description
Default
(Range)
b5-66
(11DE)
PID Feedback Monitor Level
Sets the signal level for the monitor specified in
b5-55 [PID Feedback Monitor Selection]
.
0
(0, 1)
0 : Absolute
1 : Bi-directional (+/-)
■
b5-67: PID Differential FB Monitor Lvl
No.
(Hex.)
Name
Description
Default
(Range)
b5-67
(11DF)
PID Differential FB Monitor
Lvl
Sets the signal level for the monitor specified in
b5-63 [PID Differential FB Monitor Sel]
.
0
(0, 1)
0 : Absolute
1 : Bi-directional (+/-)
■
b5-89: Sleep Method Selection
No.
(Hex.)
Name
Description
Default
(Range)
b5-89
(0B89)
RUN
Sleep Method Selection
Sets sleep and wake up operation when using PID.
0
(0, 1)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание GA500 series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 456: ...2 12 T Auto Tuning 456 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 488: ...3 8 Test Run Checklist 488 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 494: ...4 3 Remove and Reattach the Keypad 494 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 514: ...5 6 Connect the Drive to a PC 514 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 525: ...YASKAWA TOEPYAIGA5002A GA500 Programming 525...