5.2 Address assignment
Sub module
Input address
Access
Assignment
AI5/AO2
800
WORD
Analog input channel 0 (X4)
802
WORD
Analog input channel 1 (X4)
Sub module
Input address
Access
Assignment
DI24/DO16
136
BYTE
Digital input I+0.0 ... I+0.7 (X4)
137
BYTE
Digital input I+1.0 ... I+1.7 (X4)
Sub module
Input address
Access
Assignment
Counter
816
DINT
Channel 0: Counter value / Frequency value
820
DINT
Channel 1: Counter value / Frequency value
824
DINT
Channel 2: Counter value / Frequency value
828
DINT
Channel 3: Counter value / Frequency value
Sub module
Output address
Access
Assignment
Counter
816
DWORD
reserved
820
DWORD
reserved
824
DWORD
reserved
828
DWORD
reserved
Sub module
Output address
Access
Assignment
DI24/DO16
136
BYTE
Digital output Q+0.0 ... Q+0.7 (X5)
137
BYTE
Digital output Q+1.0 ... Q+1.3 (X5)
5.3 Analog input
5.3.1 Properties
n
2xUx12Bit (0 ... 10V) fixed.
n
The analog channels of the module are not isolated to the electronic power supply.
n
The analog part has no status indication.
Temporarily not used analog inputs must be connected to the concerning
ground.
VIPA System SLIO
Deployment I/O periphery
Analog input > Properties
HB300 | CPU | 013-CCF0R00 | en | 16-40
91