Event ID
Description
0xE401
FSC card was removed
DatID : FeatureSet Trialtime in minutes
ZInfo1 : Memory extension in kB
ZInfo2 : FeatureSet PROFIBUS
ZInfo2 : FeatureSet field bus
ZInfo2 : FeatureSet motion
ZInfo2 : Reserved
ZInfo3 : Source of the FSC
0: CPU
1: Card
0xE402
A configured functionality is not activated
ZInfo1 : FCS ErrorCode
1: The PROFIBUS functionality is disabled The interface acts further as MPI interface
2: The EtherCAT functionality is not enabled
3: The number of configured axis is not enabled
0xE403
FSC can not be activated in this CPU
ZInfo1 : Memory extension in kB
ZInfo2 : FeatureSet PROFIBUS
ZInfo2 : FeatureSet field bus
ZInfo2 : FeatureSet motion
ZInfo2 : Reserved
0xE404
FeatureSet deleted due to CRC error
DatID : Not relevant to the user
0xE405
The trial time of a feature set or MMC has expired
DatID : Not relevant to the user
0xE410
A CPU feature set was activated
DatID : Not relevant to the user
0xE500
Memory management: Deleted block without corresponding entry in BstList
ZInfo2 : Block type
0x38: OB
0x41: DB
0x42: SDB
0x43: FC
0x44: SFC
0x45: FB
0x46: SFB
0x6F: VOB
0x65: VFB
0x63: VFC
0x61: VDB
0x62: VSDB
VIPA System SLIO
System specific event IDs
HB300 | CPU | 013-CCF0R00 | en | 16-40