122
CHAPTER2 PROFIBUS Unit
(23) Specified point data read ....................................................... Code 0217
The specified point data is read.
Command option
QWn+22
QWn+20
QWn+18
QWn+16
QWn+14 QWn+12
Point number
Command response
IWm+22
IWm+20
IWm+18
IWm+16
IWm+14 IWm+12
Y axis position
X axis position
(Details)
Point number:
It is the inherent number of 0 to 999 assigned to each point.
(Example)
Transmission example 1:
Data of P254 is read.
QWn+22 QWn+20 QWn+18 QWn+16 QWn+14 QWn+12 QWn+10
QWn+8
0000
0000
0000
0000
0000
00FE
0000
0217
Response example 1:
The shift data is X=-0.05, Y=0.01.
IWm+22
IWm+20
IWm+18
IWm+16
IWm+14 IWm+12 IWm+10
IWm+8
0000
0001
FFFF
FFFB
0000
0000
0000
0200