35
CHAPTER2 PROFIBUS Unit
2-9
I/O assignment change function
2-9-1
Changing the I/O assignment
The I/O assignment change function changes the function assigned to each input/output
(I/O) signal.
I/O assignment can be changed by setting the I/O assignment selection parameter (single-
axis controllers: PRM59, dual-axis controller: PRM26). For the contents of I/O assign-
ment, refer to "2-9-2 I/O assignment list". Also refer to "2-9-3 I/O assignment selection
parameter description" for details on the I/O assignment selection parameter and "2-9-4
Input/output signal description" for details on each input/output signal used for I/O as-
signment selection. After changing the I/O assignment, the controller must be restarted
to enable the changes.
M E M O
M E M O
The I/O assignment change function is supported by the following controller ver-
sions:
ERCX, SRCX : Ver. 13.57 or later
DRCX
: 18.57 or later
SRCP, SRCD
: Ver. 24.17 or later
SRCP30
: Ver. 24.30H or later