95
CHAPTER2 PROFIBUS Unit
(29) Subtraction of specified value
from counter variable D ........................................................ Code 011D
The specified value is subtracted from the counter variable D.
Command option
QWn+22
QWn+20
QWn+18
QWn+16
QWn+14 QWn+12
Subtraction value
Command response
IWm+22
IWm+20
IWm+18
IWm+16
IWm+14 IWm+12
(Details)
Addition value:
A value of 1 to 65535 can be specified.
(Example)
Transmission example 1:
10 is subtracted from the counter variable D.
QWn+22 QWn+20 QWn+18 QWn+16 QWn+14 QWn+12 QWn+10
QWn+8
0000
0000
0000
0000
0000
000A
0000
011D
Response example 1:
It is normally ended.
IWm+22
IWm+20
IWm+18
IWm+16
IWm+14 IWm+12 IWm+10
IWm+8
0000
0000
0000
0000
0000
0000
0000
0200