126
CHAPTER2 PROFIBUS Unit
(4) Point data write....................................................................... Code 0304
The data is written into the specified point.
Command option
QWn+22
QWn+20
QWn+18
QWn+16
QWn+14 QWn+12
Y axis position
X axis position
Axis
Point number
Command response
IWm+22
IWm+20
IWm+18
IWm+16
IWm+14 IWm+12
(Details)
Point number:
It is the inherent number of 0 to 999 assigned to each point.
Axis:
0 means all axes, 1 means X axis and 2 means Y axis. On dual-axis
controllers, all axes are also specified when 3 is set.
On single-axis controllers, 0 or 1 alone can be specified.
Axis data:
The position data desired to register is directly specified (Unit:
0.01 mm). When the rotary axis is set for the robot, the unit of the
movement position is 0.01 degrees. If any axis is specified, the
data of other axes not specified is free. It does not matter that the
data of Y axis is free in single-axis controllers.
(Example)
Transmission example 1:
X=25.00 and Y=10.00 are written into P100.
QWn+22 QWn+20 QWn+18 QWn+16 QWn+14 QWn+12 QWn+10
QWn+8
0000
03E8
0000
09C4
0000
0064
0000
0304
Response example 1:
It is normally ended.
IWm+22
IWm+20
IWm+18
IWm+16
IWm+14 IWm+12 IWm+10
IWm+8
0000
0000
0000
0000
0000
0000
0000
0200