– Determine that the drain plug and air drain plug of water separator are
tightened.
If the air bleed plug is not tightened, the air in fuel system won’t be
exhausted.
– Ensure the fuel ball valve in the bottom of fuel tank has been opened.
– Loosen the air bleed plug on the fuel filter.
– Loosen the hand wheel on fuel supply pump and move the plunger up
and down until no air bubbles are seen from the air bleed plug.
– Tighten the air bleed plug and continue to move the plunger of fuel
supply pump up and down until the load becomes heavier.
– Push down the hand wheel of fuel supply pump and tighten it.
Start the engine and run it at low speed
and empty load.
– Hang “No Operation” nameplate to the operating lever.
– Pull the safety locking rod to Lock position.
– Check the hydraulic system for leaks.