![XCMG XE17U Скачать руководство пользователя страница 101](http://html.mh-extra.com/html/xcmg/xe17u/xe17u_instruction-manual_882151101.webp)
09.2020
Seite 91 / 197
Jump-starting the excavator
Warning!
The battery generates explosive gases while charging or being used.
keep the area around it free of sparks or static electricity.
1. Charge the battery at a well-ventilated place.
2. When starting a facility with jumper cables, wear safety goggles.
3. Wrong jump-starting procedure may result in an explosion and cause
severe injuries.
4. Start on a dry and firm ground but avoid ungrounded metallic roads or
surfaces.
5. When starting with other equipment connected, make sure that the facilities
do not contact.
6. When charging, connect the positive pole of the subsidiary battery to that of
the feeding battery and the negative pole of the former to bracket of the
latter.
7. When installing the battery, connect the positive connection poles first,
when dismounting it, start by removing the negative pole.
Warning!
The voltage of the electrical machine is 12V (negative ground). During assisted
start, be sure to use a 12V boosting battery of the same capacity.
5.2.4.1 Connecting boosting battery
Notice
When starting, follow the steps below to use the assisted or
boosting battery start method after the feeding is done.
1. Shut off the engine on the equipment connected with the
boosting battery.
2. Connect one end of the red wire (a) to the positive pole of the
battery on the excavator and the other end to that of the
boosting battery(c).
3. Connect one end of the black wire (b) to the negative pole of
the boosting battery and the other end to the upper bracket (e)
on the excavator for grounding.
4. When connecting the upper bracket, keep connections away
from the battery as far as possible and do not connect it to the
negative pole of the battery directly.
5. Start the engine.
5.2.4.2 Removing boosting battery
Notice
Follow the steps below to remove boost-battery.
1. First, remove the black negative connection (b) from the
main frame of the equipment.
2. Remove the other end of the black negative connection
from the boosting battery.
3. Remove the red positive connection (a) from the boosting
battery.
4. Then, remove the other end of the red positive connection
(a) from the battery on the excavator.