Watlow EZ-ZONE
®
RMC Module
•
202
•
Chapter 7 Features
Process Value
Add
Process Value
Absolute
Difference
Source Function A
Source Instance A
Source Error A
Source Function B
Source Instance B
Source Zone B
Source Error B
Source Function C
Source Instance C
Source Zone C
Source Error C
Source Function D
Source Instance D
Source Zone D
Source Error D
Source Function E
Source Instance E
Source Zone E
Source Error E
Source Function A
Source Instance A
Source Error A
Source Function B
Source Instance B
Source Zone B
Source Error B
Source Function C
Source Instance C
Source Zone C
Source Error C
Source Function D
Source Instance D
Source Zone D
Source Error D
Source Function E
Source Instance E
Source Zone E
Source Error E
Source Value A
Source Value B
Source Value C
Source Value D
Source Value E
Source Value A
Source Value B
Source Value C
Source Value D
Source Value E
Output Value
Error
Output Value
Error
Pressure Units
Altitude Units
Barometric Pressure
Cross Over P
oint
Cross Over Band
Function
Filter Offset
Pressure Units
Altitude Units
Barometric Pressure
Cross Over P
oint
Cross Over Band
Function
Filter Offset
Output Value = Filter [(A + B + C + D) + Offset]
Display units follows last temperature source
else follow Source A
Output Value = Filter [| A - B | + Offset]
Display units follow Source A plus relative
Source B
Process Value
Multiply
Process Value
Minimum
Output Value = Filter [(A * B * C * D) + Offset]
Display units follows last temperature source
else follow Source A
Output Value = Filter [Minimum Value (A : B : C : D) +
Offset]
Display units follows Source with minimum value.
Source Function A
Source Instance A
Source Error A
Source Function B
Source Instance B
Source Zone B
Source Error B
Source Function C
Source Instance C
Source Zone C
Source Error C
Source Function D
Source Instance D
Source Zone D
Source Error D
Source Function E
Source Instance E
Source Zone E
Source Error E
Source Function A
Source Instance A
Source Error A
Source Function B
Source Instance B
Source Zone B
Source Error B
Source Function C
Source Instance C
Source Zone C
Source Error C
Source Function D
Source Instance D
Source Zone D
Source Error D
Source Function E
Source Instance E
Source Zone E
Source Error E
Source Value A
Source Value B
Source Value C
Source Value D
Source Value E
Source Value A
Source Value B
Source Value C
Source Value D
Source Value E
Output Value
Error
Output Value
Error
Pressure Units
Pressure Units
Altitude Units
Altitude Units
Barometric Pressure
Barometric Pressure
Cross Over P
oint
Cross Over P
oint
Cross Over Band
Cross Over Band
Function
Function
Filter
Filter
Offset
Offset