Chapter 4 Setup Page
RMC Module • Setup Page
Dis-
play
Parameter Name
Description
Range
Default
Modbus
Relative
Address
CIP
Class
Instance
Attribute
hex (dec)
Profibus
Index
Parameter
ID
Data
Type
& Read/
Write
[`o;S3]
[ o.S3]
Special Output (1 to 4)
Output 3 Size
0 to 9,999
0
5018
[offset 80]
0x87 (135)
1 to 4
0x1E (30)
- - - -
35030
float
RWES
[`o;S4]
[ o.S4]
Special Output (1 to 4)
Output 4 Size
0 to 9,999
0
5020
[offset 80]
0x87 (135)
1 to 4
0x1F (31)
- - - -
35031
float
RWES
[`t;dL]
[ t.dL]
Special Output (1 to 4)
Time Delay
If Function is set to Se-
quencer:
• Set in seconds to rep-
resent the minimum
span of time that
must elapse between
the turn on of one
(on-off) output to the
next.
0 to 9,999 seconds
0
5010
[offset 80]
0x87 (135)
1 to 4
0x1A (26)
- - - -
35026
uint
RWES
[`ot;o]
[ ot.o]
Special Output (1 to 4)
Output Order
If Function is set to Se-
quencer:
• Set to Linear to turn
the on-off outputs
on in the same order
every time. Select
Progressive to rotate
the order to balance
usage and wear on
contactors and heat-
ers.
[`Lin]
Linear (1509)
[`Pro]
Progressive (1510)
Linear
5012
[offset 80]
0x87 (135)
1 to 4
0x1B (27)
- - - -
35027
uint
RWES
[`uAr]
[`Set]
Variable Menu
[tyPE]
[tyPE]
Variable 1 to 8
Data Type
Set the variable's data
type.
[AnLg]
Analog (1215)
[`Dig]
Digital (1220)
Analog
4800
[offset 20]
0x66 (102)
1 to 8
1
210
2001
uint
RWES
[Unit]
[Unit]
Variable 1 to 8
Units
Set the variable's units.
Note:
Units are always in de-
grees F when used for
temperature
[`A;tp]
Absolute Temperature
(1540)
[`r;tp]
Relative Temperature
(1541)
[PWr]
Power (73)
[`Pro]
Process (75)
[``rh]
Relative Humidity
(1538)
[nonE]
None (61)
Absolute
Temper-
ature
4812
[offset 20]
0x66 (102)
1 to 8
7
- - - -
2007
uint
RWES
[`Dig]
[ dig]
Variable 1 to 8
Digital
Set the variable's value.
[`oFF]
Off (62)
[``on]
On (63)
Off
4802
[offset 20]
0x66 (102)
1 to 8
2
211
2002
uint
RWES
[anLg]
[AnLg]
Variable 1 to 8
Analog
Set the variable's value.
-1,999.000 to 9,999.000
0.0
4804
[offset 20]
0x66 (102)
1 to 8
3
212
2003
float
RWES
Note:
Some values will be rounded off to fit in the four-character display .
Full values can be read with other interfaces .
Note:
If there is only one instance of a menu, no submenus will appear .
** These parameters/prompts are available in these menus with firmware revisions 6 .0 and
above .
R: Read
W: Write
E:
EEPROM
S: