Watlow EZ-ZONE
®
RMC Module
•
95
•
Chapter 4 Setup Page
RMC Module • Setup Page
Dis-
play
Parameter Name
Description
Range
Default
Modbus
Relative
Address
CIP
Class
Instance
Attribute
hex (dec)
Profibus
Index
Parameter
ID
Data
Type
& Read/
Write
[SFn;b]
[SFn.b]
Logic (1 to 4)
Source Function B
Set the type of function
that will be used for this
source.
[none]
None (62)
[ALM]
Alarm (6)
[`C;Pr]
Cool Power, Control
Loop (161)
[`CPE]
Compare (230)
[`Ctr]
Counter (231)
[`dio]
Digital I/O (1142)
[Ent;A]
Profile Event Out A
(233)
[Ent;b]
Profile Event Out B
(234)
[Ent;C]
Profile Event Out C
(235)
[Ent;d]
Profile Event Out D
(236)
[Ent;E]
Profile Event Out E
(247)
[Ent;F]
Profile Event Out F
(248)
[Ent;g]
Profile Event Out G
(249)
[Ent;h]
Profile Event Out H
(250)
[`FUn]
Function Key (1001)
[lim]
Limit (126)
[`lgC]
Logic (239)
[SoF;1]
Special Function Output
1 (1532)
[SoF;2]
Special Function Output
2 (1533)
[SoF;3]
Special Function Output
3 (1534)
[SoF;4]
Special Function Output
4 (1535)
[tMr]
Timer (244)
[`uAr]
Variable (245)
None
3682
[offset 80]
0x7F (127)
1 to 4
2
- - - -
27002
uint
RWES
[`Si;B]
[ Si.b]
Logic (1 to 4)
Source Instance B
Set the instance of the
function selected above.
1 to 24
1
3698
[offset 80]
0x7F (127)
1 to 4
0xA (10)
- - - -
27010
uint
RWES
{`S2;B]
[ SZ.b]
Logic (1 to 4)
Source Zone B
Set the zone of the func-
tion selected above
0 to 16
0
3714
[offset 80]
0x7F (127)
1 to 4
0x12 (18)
- - - -
27018
uint
RWES
Note:
Some values will be rounded off to fit in the four-character display .
Full values can be read with other interfaces .
Note:
If there is only one instance of a menu, no submenus will appear .
** These parameters/prompts are available in these menus with firmware revisions 6 .0 and
above .
R: Read
W: Write
E:
EEPROM
S:
User Set