Watlow EZ-ZONE
®
RMC Module
•
53
•
Chapter 3 Operations Page
RMC Module • Operations Page
Display
Parameter Name
Description
Range
Default
Modbus
Relative
Address
CIP
Class
Instance
Attribute
hex (dec)
Profibus
Index
Parameter
ID
Data
Type
& Read/
Write
[P;SP4]
[P.SP4]
Profile Status
Produced Set Point 4
Display the current set
point, even if the profile
is ramping.
-1,999.000 to 9,999.000°F or
units
-1,128.000 to 5,537.000°C
- - - -
5384
- - - -
- - - -
22053
float
R
No Dis-
play
Profile Status
Produced Control
Mode 1
Display the current
control mode.
Off (62)
Auto (10)
Manual (54)
- - - -
5366
0x7A
(122)
1
0x2C (44)
- - - -
22044
uint
R
No Dis-
play
Profile Status
Produced Control
Mode 2
Display the current
control mode.
Off (62)
Auto (10)
Manual (54)
- - - -
5368
0x7A
(122)
1
0x2D (45)
- - - -
22045
uint
R
No Dis-
play
Profile Status
Produced Control
Mode 3
Display the current
control mode.
Off (62)
Auto (10)
Manual (54)
- - - -
5370
0x7A
(122)
1
0x2E (46)
- - - -
22046
uint
R
No Dis-
play
Profile Status
Produced Control
Mode 4
Display the current
control mode.
Off (62)
Auto (10)
Manual (54)
- - - -
5372
0x7A
(122)
1
0x2F (47)
- - - -
22047
uint
R
[hoUr]
[hoUr]
Profile Status
Hours
Step time remaing in
hours.
0 to 99
0
5434
0x7A
(122)
1
0x4E (78)
- - - -
22078
uint
RW
[min]
[ Min]
Profile Status
Minutes
Step time remaing in
minutes.
0 to 59
0
5432
0x7A
(122)
1
0x4D (77)
- - - -
22077
uint
RW
[`seC]
[ SEC]
Profile Status
Seconds
Step time remaing in
seconds.
0 to 59
0
5430
0x7A
(122)
1
0x4C (76)
- - - -
22076
uint
RW
No Dis-
play
Profile Status
Wait for Event Source
Value 1
Read the present state
of event input 1.
[`off]
Off (62)
[``on]
On (63)
- - - -
5346
0x7A
(122)
1
0x22 (34)
- - - -
22034
uint
R
No Dis-
play
Profile Status
Wait for Event Source
Value 2
Read the present state
of event input 1.
[`off]
Off (62)
[``on]
On (63)
- - - -
5348
0x7A
(122)
1
0x23 (35)
- - - -
22035
uint
R
No Dis-
play
Profile Status
Wait for Event Source
Value 3
Read the present state
of event input 1.
[`off]
Off (62)
[``on]
On (63)
- - - -
5350
0x7A
(122)
1
0x24 (36)
- - - -
22036
uint
R
Note:
Some values will be rounded off to fit in the four-character display . Full values can be
read with other interfaces .
Note:
If there is only one instance of a menu, no submenus will appear .
** These parameters/prompts are available in these menus with firmware revisions 6 .0
and above .
R: Read
W: Write
E: EEPROM
S: User Set