Cotter Corporation (N.S.L.)
Cañon City Milling Facility
Cañon City, Colorado
Procedure
Arkansas River Water
Sample Collection
Number: SOP-E-090
Page: 3 of 9
Revision: 1
Date: --/--/--
5.1.1
Model D74TM integrated depth sampler.
5.1.2
USGS AA Current Meter.
5.1.3
Bucket.
5.1.4
Churnsplitter.
5.1.5
Various booms, rods, cables and winches.
5.1.6
pH meter.
5.1.7
Electrical conductivity meter.
5.1.8
Temperature meter.
5.1.9
Field sampling logbook, field data sheet, or tablet.
5.1.10
Waterproof marking pens.
5.2
MATERIALS
5.2.1
New polyethylene sample bottles.
5.2.2
4,7, and 10 pH buffers.
5.2.3
Appropriate electrical conductivity standards.
5.2.4
SSTF.
5.2.5
Decontamination equipment and supplies, (See Procedure SOP-E-044).
5.3
MAINTENANCE/CALIBRATION
5.3.1
Refer to the specific instruments operating instruction manual for
calibration, troubleshooting and maintenance.
6.0
HEALTH AND SAFETY
6.1
Sample technicians should be certain all mechanical equipment is in good repair
and properly maintained before attempting its use.
6.2
When taking a grab sample care should be taken because rocks along the banks of
the river can be slippery.
6.3
Traffic safety when working near roadways.