Cotter Corporation (N.S.L.)
Cañon City Milling Facility
Cañon City, Colorado
Procedure
Field Global Positioning
System Surveying
Number: SOP-E-140
Page: 4 of 7
Revision: 1
Date: May 2016
7.3.2
Following items listed within this procedure.
8.0
EQUIPMENT SETUP INSTRUCTIONS
8.1
Verify batteries in both receivers and data collector unit are charged.
8.2
Proceed to base station location.
8.3
At base station location attach antenna to receiver.
8.4
Attach base receiver to base station rod.
8.5
Turn on base station receiver.
8.6
Turn on data collector.
8.7
From toolbar on TopCon FC-200 data collector screen:
8.7.1
Select
Setup
icon.
8.7.2
From setup menu select
Base station.
8.7.3
Follow menu prompts, press next to advance.
8.7.3.1
Connection (Pocket-3D)
8.7.3.1.1
COM6: (BlueTooth)
8.7.3.2
Antenna type:
8.7.3.2.1
TopCon HiPer GB
8.7.3.2.2
Antenna height 0.000’
8.7.3.2.3
Measured to Rim
8.7.3.3
Radio type:
8.7.3.3.1
TopCon Digital (UHF)
8.7.3.3.2
Serial Port C
8.7.3.3.3
38400 Baud rate
8.7.3.3.4
CMR Format
8.7.3.4
GPS receiver settings:
8.7.3.4.1
Use co-op tracking
8.7.3.4.2
Use multipath reduction
8.7.4
Select
Finish
icon on toolbar.