Virginia Controls, LLC
MH-3000 User Manual, 1_03C10-VC
Page 88
•
Do Not Run on Fire Service and Shutdown
–
Turn this feature on to prevent the car
from running if Fire Service is enabled while on shutdown. If this feature is not enabled
the car will be allowed to run down on Fire Serviec and shutdown.
•
Allow Door Zone Fault on Fast Speed
–
Turn this feature on to allow the Door Zone
Fault to be initiated if the car is running fast speed and the input is on. False trips are
prevented by the Leveling Cutout Timer, which prevents a fault as the car starts, and
before the FSU/FSD relays energize.
•
Allow Stop at Upper Floor on Shutdown
–
Turn this feature on to allow the car to
stop at an upper floor on shutdown if it is the main floor. Check with the appropriate
codes to see if this is allowed or required.
•
Enable CKO on Independent
–
Turn this feature on to energize the CKO Car Call
Cutout Override output on Independent Service. This will allow car calls to be registered
without the use of access keys.
•
Dir Indicators show actual direction on Attend.
–
Turn this feature on to make the
Attendant Direction Indicators show the direction that the car will run next. If this
feature is not enabled then they will show whether there are calls registered in either
direction. For example, with this feature off, and the car at an intermediate floor with
calls above and below the car, then both Attendant Direction Indicators would be on,
since there are calls above and below the car. If the feature was enabled, then the
indicators woul be the same as the normal Direction Indicators, and only one indicator
would be on, depending on which direction had actually been selected.
•
Med Emerg Buzzer on Independent only
–
Turn this feature on to change the
operation of the Medical Emergency Buzzer output. With the feature disabled (factory
default) the buzzer will come on while the car is returning to the Medical Emergency
floor in response to the hall Medical Emergency Switch. If the feature is enabled, the
buzzer will come on if the car is on Independent Service and a hall Medical Emergency
Switch is turned on. This alerts the operator to release the car.
•
Enable Full Redundancy Fault Checking
–
Turn this feature on to enable Redundancy
Fault checking with the MH5 board. This enables additional inputs used to check critical
circuits. The inputs for this feature must have been assigned for this feature to work
properly.
NOTE: Switch 3 on the CPU Dip Switches is a Redundancy Defeat. If this is
turned ON, then this will prevent a fault from the Redundancy checks, or a
Door Zone Fault. The Fire Buzzer will be turned on to remind you to turn off
the Redundancy Defeat after installation.
•
Always Enable DOB at Front Openings
–
Turn this feature on to allow the Front Door
Open Button to always open the doors at selective openings (where there is a front and
rear opening at the same landing). With this feature disabled, the doors must have
been opened, or still be open, for the Door Open Button to operate. This allows a
measure of security at these landings.
•
Always Enable DOB at Rear Openings
–
Turn this feature on to allow the Rear Door
Open Button to always open the doors at selective openings (where there is a front and
rear opening at the same landing). With this feature disabled, the doors must have
been opened, or still be open, for the Door Open Button to operate. This allows a
measure of security at these landings.
•
Disable Non-Shutdown Faults in the Fault Log
–
Turn this feature on to disable
faults from being logged into the Fault Log that are not shutdown faults. This keeps the