VC4000 Manual
66
VC
4000
Setu
p
If your VC4000 is not working properly it may be that some of the
settings were
inadvertently changed
. A common problem is when
the G-Threshold gets changed to some small number the unit will
activate too soon. Try setting defaults to see if that restores it to
normal operation. Note that this will change all settings except User
Type. The user variables will be set to the values of:
G-Threshold = 0.200 (See note below)
Vehicle ID = 0
Pitch/Roll Factors = 1 (G adjust = 0.9700)
User Type = Unchanged
Units = Imperial
RS232 Port/Printer = Port 1
Brake MPH = 20
Sensors
o
(PC) OBDII Sensors: All OFF
o
Analog out = OFF
o
(PC) GPS Sensors: All OFF
Accelerometer
o
G Summation = Summation 3D (XYZ)
o
G Smoothing = 3
o
Zeroing ON/OFF = ON
o
(PC) Accel Range = 2G
o
G Adjust = 0.9700 (Pitch/Roll = 1)
o
Graph Range = 1.0
o
Alarm Threshold = 0.0
o
(PC) Sample Rate = 100
Performance
o
Vehicle Weight = 1000
o
Countdown = OFF
G Threshold note: Units shipped with requested New York State
specifications have a default threshold of 0.100 G.
To set Defaults:
1. Select
Set Defaults
from the Setup menu
2. Press
ENTER / YES
.
3. Press
ENTER / YES
again.
Set Defaults