52
The VC4000PC stores the file as a monitor mode file so when
importing to profile it will be an acceleration test, not a braking test.
Start Crash mode:
1.
From the “READY” screen press the Tools key, then select
Crash Mode
with the vehicle at a complete stop. The
VC4000 will zero adjust the accelerometers and applicable
sensors, show the available record time in seconds, display
the run number being saved, and then display:
2. Accelerate the car to the desired initial speed. After
reaching that speed, trigger the VC4000PC using the
external trigger or it will activate when it impacts an object
and generates ±4xG-Threshold or more.
The VC4000 accelerometer
calibration
can be checked easily using
this tool. No setup changes are necessary when checking
calibration this way. Select
Cal. Check
from the list. The VC4000
will prompt you to turn it onto its back, front, each side, top and
bottom. The VC4000 does not need to be periodically calibrated.
Vericom offers calibration certificates for those that require annual
calibration.
This check can be done on a reasonably level desk. All connectors
should be unplugged from the back of the unit when performing this
check. The Arm for the single suction cup mount should be
disconnected from the ball on the VC4000.
AUTO START READY
Cal. Check
ON BACK (-1Gx)
ON FRONT (+1Gx)
ON RIGHT SIDE (-1Gy)
ON LEFT SIDE (+1Gy)
ON TOP (-1Gz)
ON BOTTOM (+1Gz)
Mode – Cal. Check