17
Slope A = -0.1
Slope C = +0.1
Zero adjust at point B
Do skid test at point A, B or C
f = µ = 0.800
Zero adjust at point A
Zero adjust a point C
Do skid test at point A
Do skid test at point C
f = µ - slope
f = µ + slope
-0.8 (-) +0.1 = -0.7
-0.8 (+) -0.1 = -0.9
-0.8 + 0.1 = -0.7
-0.8
– 0.1 = -0.9
VC4000 will display -0.700 Ave G
VC4000 will display -0.900 Ave G
Attaching accessories
It may be easier to plug in cables before mounting the VC4000. If
you do not wish to use the batteries on the VC4000 plug the
provided power cord into back of VC4000 and into vehicle's
accessory jack if one is available. Plug the external activation
connector into VC4000 if you are using it (see page 86 for external
activation). Plug in VSI or GPS if needed (PC).
Figure 9: VC4000 back panel
VC4000 Run Storage Memory
The VC4000 stores all braking runs to internal
flash memory
.
Eventually the memory will fill up or the number of files will exceed