M3000
Installation Manual
78
Facility Commander Wnx and Secure Perfect
The following Secure Perfect device addresses are created for you by the Secure Perfect software. This table is
provided for your reference only. The device address is in the format
mmmm-b-pp
where
mmmm
represents the
controller number,
b
represents the board number, and
pp
represents the point or device number.
Table 20. 8RP device addressing - Picture Perfect Board 2
Board type: Board 2
1
1.
The second 8 readers out of 16. See
Table 23
on page 80 for board type settings.
Reader 9 and 10
Reader 11 and 12
Reader 13 and 14 Reader 15 and 16
Picture Perfect board number
5
6
7
8
Readers
0 and 1
0 and 1
0 and 1
0 and 1
Door DIs
0 and 1
0 and 1
0 and 1
0 and 1
Exit DIs
8 and 9
8 and 9
8 and 9
8 and 9
Door DOs
0 and 1
0 and 1
0 and 1
0 and 1
Table 21. 8RP device addressing - Facility Commander Wnx and Secure Perfect
Standard/Board 1
Board 2
Readers/Door DO
mmmm
-1-01
through
mmmm
-1-08
mmmm
-2-01
through
mmmm
-2-08
Door DIs
mmmm
-1-01
through
mmmm
-1-08
mmmm
-2-01
through
mmmm
-2-08
Exit DIs
mmmm
-1-01
through
mmmm
-1-08
mmmm
-2-01
through
mmmm
-2-08
Содержание M3000
Страница 1: ...M3000 Installation Manual P N 460630001H 15JUNE11 ...
Страница 10: ...M3000 Installation Manual x ...
Страница 37: ...Chapter 3 Power Communications board 27 Host computer wiring Figure 9 Wiring host computer to first M3000 ...
Страница 39: ...Chapter 3 Power Communications board 29 Figure 11 Wiring modem to M3000 M 5 or serial printer ...
Страница 41: ...Chapter 3 Power Communications board 31 Figure 13 Wiring downstream away from the host using RS 232 ...
Страница 47: ...Chapter 4 PXNplus CPU board 37 Board layout Figure 16 PXNplus CPU board layout ...
Страница 58: ...M3000 Installation Manual 48 Board layout Figure 17 2RP reader board layout ...
Страница 65: ...Chapter 5 Reader processing boards 55 Figure 21 Wiring 2RP to Wiegand Strobed F 2F and supervised F 2F readers ...
Страница 68: ...M3000 Installation Manual 58 Figure 24 Wiring 2RP door strike external relay ...
Страница 72: ...M3000 Installation Manual 62 Board layout Figure 27 2SRP supervised reader board layout ...
Страница 78: ...M3000 Installation Manual 68 Figure 30 Wiring 2SRP to Wiegand F 2F Strobed and Supervised F 2F Readers ...
Страница 82: ...M3000 Installation Manual 72 Figure 19 Wiring 2SRP door alarm contact and exit request ...
Страница 84: ...M3000 Installation Manual 74 Figure 21 Wiring 2SRP door strike external relay ...
Страница 89: ...Chapter 5 Reader processing boards 79 Board layout Figure 24 8RP reader board layout ...
Страница 92: ...M3000 Installation Manual 82 Figure 26 Wiring 8RP to F 2F or Supervised F 2F Readers ...
Страница 94: ...M3000 Installation Manual 84 ...
Страница 97: ...Chapter 6 Optional DI and DO boards 87 Figure 31 20DI board layout ...
Страница 99: ...Chapter 6 Optional DI and DO boards 89 Figure 32 Wiring DI point ...
Страница 101: ...Chapter 6 Optional DI and DO boards 91 Figure 33 16DO board layout ...
Страница 102: ...M3000 Installation Manual 92 Figure 34 16DOR board layout ...
Страница 104: ...M3000 Installation Manual 94 Figure 36 Wiring output device to 16DOR board ...
Страница 152: ...M3000 Installation Manual 142 ...
Страница 156: ...M5 controller Installation Manual 146 Figure 76 Installing ferrite ...
Страница 160: ...M5 controller Installation Manual 150 ...
Страница 172: ...M3000 Installation Manual 162 ...