RT-SVX24Q-EN
189
Service and Maintenance
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e a
an
nd
d E
Ex
xp
po
ossu
urre
e tto
o
U
Ullttrra
av
viio
olle
ett R
Ra
ad
diia
attiio
on
n!!
T
Th
hiiss p
prro
od
du
ucctt cco
on
ntta
aiin
nss cco
om
mp
po
on
ne
en
nttss tth
ha
att e
em
miitt h
hiig
gh
h--
iin
ntte
en
nssiitty
y u
ullttrra
av
viio
olle
ett ((U
UV
V--C
C)) rra
ad
diia
attiio
on
n w
wh
hiicch
h cca
an
n b
be
e
h
ha
arrm
mffu
ull tto
o u
un
np
prro
otte
ecctte
ed
d e
ey
ye
ess a
an
nd
d sskkiin
n,, a
an
nd
d cca
au
usse
e
sse
erriio
ou
uss d
da
am
ma
ag
ge
e tto
o tth
he
e e
eq
qu
uiip
pm
me
en
ntt..
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ecctt p
po
ow
we
err b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d
rre
essu
ulltt iin
n b
bu
urrn
nss o
orr e
elle
eccttrro
occu
uttiio
on
n w
wh
hiicch
h cco
ou
ulld
d rre
essu
ulltt
iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
D
Diisscco
on
nn
ne
ecctt a
allll e
elle
eccttrriicca
all p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diisscco
on
nn
ne
eccttss,, a
an
nd
d m
ma
akke
e ssu
urre
e tth
he
e U
UV
V lliig
gh
httss a
arre
e o
offff
b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err llo
occkko
ou
utt//tta
ag
go
ou
utt
p
prro
occe
ed
du
urre
ess tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err cca
an
nn
no
ott b
be
e
iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d..
T
Trra
an
ne
e d
do
oe
ess n
no
ott rre
ecco
om
mm
me
en
nd
d ffiie
elld
d iin
nsstta
alllla
attiio
on
n o
off
u
ullttrra
av
viio
olle
ett lliig
gh
httss iin
n iittss e
eq
qu
uiip
pm
me
en
ntt ffo
orr tth
he
e iin
ntte
en
nd
de
ed
d
p
pu
urrp
po
osse
e o
off iim
mp
prro
ov
viin
ng
g iin
nd
do
oo
orr a
aiirr q
qu
ua
alliitty
y.. T
Trra
an
ne
e
a
acccce
ep
pttss n
no
o rre
essp
po
on
nssiib
biilliitty
y ffo
orr tth
he
e p
pe
errffo
orrm
ma
an
ncce
e o
orr
o
op
pe
erra
attiio
on
n o
off o
ou
urr e
eq
qu
uiip
pm
me
en
ntt iin
n w
wh
hiicch
h u
ullttrra
av
viio
olle
ett
d
de
ev
viicce
ess w
we
erre
e iin
nsstta
alllle
ed
d o
ou
uttssiid
de
e o
off tth
he
e T
Trra
an
ne
e ffa
acctto
orry
y
o
orr iittss a
ap
pp
prro
ov
ve
ed
d ssu
up
pp
plliie
errss..
Table 66.
Control settings and time delays
Control
Description
Elec.
Designa-
tion
Contacts
Open
Contacts
Closed
Combustion
Airflow Switch
(Gas Heat
Only)
4S25
see note 1
0.1 - 0.25" wc
rise in press diff
Supply
Airflow Switch
(Gas Heat
Only)
4S38
0.03 - 0.12"
wc
0.15 + 0.05" wc
rise in press diff
Freezestat
(Hydronic
Heat Only)
4S12
(N.O.) Auto
Reset
40°F
Pre-purge
Timer:
Honeywell
(Gas Heat)
4U18
internal
timing
function
2 Stage 850/
1100 MBH 60—
seconds/All
other
configurations—
30 seconds
Sequencing
Time Delay
Relay (Gas
Heat)
4DL6
N.C. - timed
to close
60 s
20%
Note:
The combustion airflow switch (4S25) differential is 0.02"
- 0.08" wc.
Table 67.
Gas heat—high limit
Tons
Fan Size (in)
Config.
Contacts
Open
Close
2500 MBh High Limit
120-162
40
DF
195
155
40
HZ
240
200
32
DF & HORZ
220
180
1800 MBh High Limit
120-162
32 &40
DF
240
200
32 &40
HZ
220
180
90-118
32
DF & HZ
240
200
36
DF & HZ
240
200
36
HZ
240
310
25
DF
240
200
25
HZ
220
180
1100 MBh High Limit
120-162
32
DF
240
200
32
HZ
200
160
40
DF & HZ
240
200
Содержание IntelliPak 2 Series
Страница 217: ...RT SVX24Q EN 217 N No ot te es s...
Страница 218: ...218 RT SVX24Q EN N No ot te es s...
Страница 219: ...RT SVX24Q EN 219 N No ot te es s...