24
RT-SVX24Q-EN
Pre-Installation
Unit Inspection
To protect against loss due to damage incurred in
transit, perform inspection immediately upon receipt of
the unit.
Exterior Inspection
If the job site inspection reveals damage or material
shortages, file a claim with the carrier immediately.
Specify the type and extent of the damage on the bill of
lading before signing. Notify the appropriate sales
representative.
IIm
mp
po
orrtta
an
ntt:: Do not proceed with installation of a
damaged unit without sales
representative’s approval.
•
Visually inspect the complete exterior for signs of
shipping damages to unit or packing material.
•
Verify that the nameplate data matches the sales
order and bill of lading.
•
Verify that the unit is properly equipped and there
are no material shortages.
•
Verify that the power supply complies with the unit
nameplate and electric heater specifications.
Inspection for Concealed Damage
Visually inspect the components for concealed damage
as soon as possible after delivery and before it is
stored.
Do NOT walk on the sheet metal base pans. Bridging
between the unit’s main supports may consist of
multiple 2 by 12 boards or sheet metal grating.
W
WA
AR
RN
NIIN
NG
G
N
No
o S
Stte
ep
p S
Su
urrffa
acce
e!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w iin
nssttrru
uccttiio
on
n b
be
ello
ow
w cco
ou
ulld
d rre
essu
ulltt iin
n
d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
D
Do
o n
no
ott w
wa
allkk o
on
n tth
he
e ssh
he
ee
ett m
me
etta
all d
drra
aiin
n p
pa
an
n.. W
Wa
allkkiin
ng
g
o
on
n tth
he
e d
drra
aiin
n p
pa
an
n cco
ou
ulld
d cca
au
usse
e tth
he
e ssu
up
pp
po
orrttiin
ng
g m
me
etta
all
tto
o cco
olllla
ap
psse
e a
an
nd
d rre
essu
ulltt iin
n tth
he
e o
op
pe
erra
atto
orr//tte
ecch
hn
niicciia
an
n
ffa
alllliin
ng
g..
If concealed damage is discovered:
•
Notify the carrier’s terminal of the damage
immediately by phone and by mail.
•
Concealed damage must be reported within 15
days.
•
Request an immediate, joint inspection of the
damage with the carrier and consignee.
•
Stop unpacking the unit.
•
Do not remove damaged material from receiving
location.
•
Take photos of the damage, if possible.
•
The owner must provide reasonable evidence that
the damage did not occur after delivery.
Repair
Notify the appropriate sales representative before
arranging unit installation or repair.
IIm
mp
po
orrtta
an
ntt:: Do not repair unit until the damage has
been inspected by the carrier’s
representative.
Storage
Store unit in a level and dry location. Use adequate
blocking under the base rail. If unit is not level and
supported adequately, damage may occur when
removing screws and opening doors.
Take precautions to prevent condensate formation
inside the unit electrical components and motors when:
•
The unit is stored before it is installed; or,
•
The unit is set on the roof curb and temporary
auxiliary heat is provided in the building.
Isolate all side panel service entrances and base pan
openings (e.g., conduit holes, S/A and R/A openings,
and flue openings) to minimize ambient air from
entering the unit until it is ready for startup.
N
No
otte
e:: Do not use the unit heater as temporary heat
without completing the startup procedures
detailed under Startup information.
The manufacturer will not assume responsibility for
equipment damage resulting from accumulation of
condensate on the unit electrical and/or mechanical
components.
Unit Clearances
Minimum Required Clearance (see Dimensional Data
chapter) illustrates the minimum operating and service
clearances for either a single or multiple unit
installation.
These clearances are the minimum distances
necessary for adequate service, cataloged unit
capacity, and peak operating efficiency. Providing less
than the recommended clearances may result in
condenser coil starvation, “short-circulating” of
exhaust and economizer airflows, or recirculation of
hot condenser air.