RT-SVX24Q-EN
169
segment into place. Be careful not to bend the
wheel frame or the segment frame with the
screwdriver.
5. Reinstall forked segment retainer(s)
N
No
otte
e:: Only applies when there is an adjacent
segment in place.
6. Close each segment retainer latch under the
segment retaining catch.
7. Rotate the wheel and repeat this sequence with the
remaining segments.
Removing and replacing the segments with a spare
set can be accomplished more quickly. Remove the
dirty segment, replace it with a clean segment, then
move to the next segment.
Filtration
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ecctt p
po
ow
we
err b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d
rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
D
Diisscco
on
nn
ne
ecctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diisscco
on
nn
ne
eccttss b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err
llo
occkko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
ess tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err
cca
an
n n
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d.. V
Ve
erriiffy
y tth
ha
att n
no
o
p
po
ow
we
err iiss p
prre
esse
en
ntt w
wiitth
h a
a v
vo
ollttm
me
ette
err..
Galvanized steel permanent filters are provided to
prevent debris from entering the energy wheel section.
The return air filters are mounted in a filter rack
underneath the energy recovery wheel, and are
accessible from either side by means of the double
access doors. The outside air filter rack is attached to
the energy recovery cassette. Use the unit filter /
evaporator coil access doors to service the energy
recovery outside air filters.
1. Disconnect all electrical power.
2. Remove all filter media from the vertical filter rack
providing air filtration for the unit evaporator coil.
3. Remove the sheet metal screws in the hinged
access panel beneath the bypass damper assembly.
4. Rotate the access panel downwards.
5. Reach in past the damper wall to access the flexible
filter puller(s). Pull them towards the evaporator
coil enough to reach the second filter in each slot of
the filter rack. Refer to
for filter
information.
Table 58.
ERW Filter Information
Galvanized
Steel Filter
Info
90-118 Ton
Low CFM
ERW Units
(in.)
90-162 Ton
Low CFM
ERW Units
(in.)
90-162 Ton
Standard
CFM ERW
Units (in.)
RA Filters
(size,
number)
24x24x1, 10
24x24x1, 10
24x24x1, 10
FA Filters
(size, number
224x24x1, 8
24x24x1, 6
24x24x1, 8
12x24x1, 2
N
No
otte
e:: Inspect these filters monthly and clean them as
necessary.
Bearing and Motor Lubrication
The wheel drive motor and wheel support shaft
bearings are permanently lubricated and no further
lubrication is necessary.
Service and Repair
Drive Belt Replacement
The drive belt is a urethane stretch belt designed to
provide constant tension throughout the life of the belt.
No periodic adjustment is required. Inspect the belt
annually for proper tracking and tension. A properly
tensioned belt will turn the wheel immediately, with no
visible slippage, when power is applied.
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ecctt p
po
ow
we
err b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d
rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
D
Diisscco
on
nn
ne
ecctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diisscco
on
nn
ne
eccttss b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err
llo
occkko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
ess tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err
cca
an
n n
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d.. V
Ve
erriiffy
y tth
ha
att n
no
o
p
po
ow
we
err iiss p
prre
esse
en
ntt w
wiitth
h a
a v
vo
ollttm
me
ette
err..
W
WA
AR
RN
NIIN
NG
G
R
Riisskk o
off E
En
ne
errg
gy
y W
Wh
he
ee
ell C
Co
olllla
ap
pssiin
ng
g!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w iin
nssttrru
uccttiio
on
nss b
be
ello
ow
w cco
ou
ulld
d cca
au
usse
e
tth
he
e e
en
ne
errg
gy
y w
wh
he
ee
ell tto
o cco
olllla
ap
psse
e u
un
nd
de
err tth
he
e
tte
ecch
hn
niicciia
an
n’’ss w
we
eiig
gh
htt w
wh
hiicch
h cco
ou
ulld
d rre
essu
ulltt iin
n sse
ev
ve
erre
e
iin
njju
urry
y..
B
Be
effo
orre
e lla
ay
yiin
ng
g a
accrro
ossss tth
he
e e
en
ne
errg
gy
y w
wh
he
ee
ell,, a
ad
dd
d e
ex
xttrra
a
ssu
up
pp
po
orrtt b
by
y p
plla
acciin
ng
g a
a rriig
giid
d b
bo
oa
arrd
d a
accrro
ossss tth
he
e ssp
pa
an
n o
off
tth
he
e e
en
ne
errg
gy
y w
wh
he
ee
ell cca
asssse
etttte
e..
1. Disconnect all electrical power.
2. Confirm the model number on the belt replacement
kit matches the model number on the label by the
motor pulley. Remove all remnants of the old belt.
3. Uncoil the belt as necessary. The belt must not twist