32
Console
panel
monitor
display
Contents
Setting range (selecting item)
Factory-
initialized
data
Unit
Driving
ReWrite
b-16
Reverse regenerative armature current
limit
0 to value that depends on rated motor
armature current <A-04>
*3
* The rated current of VF66B (DC motor drive)
is 100%
150 %
b-17
Analog input (1) characteristics
selection
0: 0 to ±10 V (bipolarity)
1: 0 to 10 V (unipolarity)
2: 4 to 20 mA
0 -
×
b-18
Analog input (1) speed/voltage upper
limit
Absolute value of analog input (1)
speed/voltage lower limit (b-19)
to 100.0
* When the operation mode selection is speed
control mode (i-07 = 0):
The maximum speed (A-00) is 100%
When the operation mode selection is
armature voltage control mode (i-07 = 5):
The forward or reverse direction output
maximum voltage (E-11, E-12) whichever is
larger is 100%
100.0 %
b-19
Analog input (1) speed/voltage lower
limit
-analog input (1) speed/voltage upper limit
(b-18)
to analog input (1) speed/voltage upper limit
(b-18)
* When the operation mode selection is speed
control mode (i-07 = 0):
The maximum speed (A-00) is 100%
When the operation mode selection is
armature voltage control mode (i-07 = 5):
The forward or reverse direction output
maximum voltage (E-11, E-12) whichever is
larger is 100%
0.0 %
b-20
Analog input zero limit voltage
0.000 to 1.000
0.000
V
b-21
Analog output (1) characteristics
selection
0: Output voltage
1: Output current
2: Armature current command
3: Speed
4: Speed command
5: Internal PLC function output
6: Calibration
7: Internal monitor
8: [For special adjustment]
8 -
×
-1: [No function]
-2: 6F speed
-3: 6F calibration
b-22
[For special adjustment]
0 to 1000
0
%
×
*1: This item is for expanded options. Normally, do not set this item.
*2: The multifunction input terminal function needs to be set to JOG command [forward rotation] or [reverse rotation]. For
information on the multifunction input function, refer to "6.4. Area c" in Chapter 6 and "7.4. Area c" in Chapter 7.