30
Console
panel
monitor
display
Contents
Setting range (selecting item)
Factory-
initialized
data
Unit
Driving
ReWrite
A-11
Dead time compensation
(P Positive side)
0.00 to 9.99
VF66B
(DC motor
drive)
Varies with
the model
*1
μ
sec ×
A-12
Dead time compensation
(P Negative side)
0.00 to 9.99
VF66B
(DC motor
drive)
Varies with
the model
*1
μ
sec ×
A-13
[For special adjustment]
*2
-
-
-
-
A-14
[For special adjustment]
*2
-
-
-
-
A-15
Dead time compensation
(N Positive side)
0.00 to 9.99
VF66B
(DC motor
drive)
Varies with
the model
*1
μ
sec ×
A-16
Dead time compensation
(N Negative side)
0.00 to 9.99
VF66B
(DC motor
drive)
Varies with
the model
*1
μ
sec ×
A-17 Motor
armature
resistance
(The setting range varies with the model of
VF66B (DC motor drive))
*1
VF66B
(DC motor
drive)
Varies with
the model
*1
m
Ω
×
A-18 [No
function]
-
-
-
-
A-19
Motor armature inductance
(The setting range varies with the model of
VF66B (DC motor drive))
*1
VF66B
(DC motor
drive)
Varies with
the model
*1
mH ×
A-20
Rated speed of tachogenerator
100 to 5000
2000 r/min
×
A-21
Voltage input to VF66B (DC motor
drive) upon rated speed of
tachogenerator
0.00 to 10.00
5.00
V
×
A-22
Field current monitoring input location
selection
0: No input
1: Analog input (1) [VFC66-Z TB1] (AIN1)
2: Analog input (2) [optional board] (AIN2)
3: Analog input (3) [optional board] (AIN3)
0 -
×
A-23
Voltage input to VF66B (DC motor
drive) upon rated field current
0.1 to 10.0
4.0
V
×
A-24 [No
function]
-
-
-
-
A-25 [No
function]
-
-
-
-
A-26 [No
function]
-
-
-
-
A-27 [No
function]
-
-
-
-
*1: Refer to "7.2. Area A" in Chapter 7 for information on the minimum value of the setting range of the rated motor
capacity (A-02), factory-initialized data of the dead time compensation (P Positive side) (A-11) to dead time
compensation (N Negative side) (A-16), setting range and factory-initialized data of the motor armature resistance
(A-17), and setting range and factory-initialized data of the motor armature inductance (A-19).
*2: This item is for special adjustment. Leave the parameter data at the factory-initialized data.