108
7.13. Area n (VF66B (DC motor drive) Mode Area)
Area n only allows contents of setting items to be viewed.
Rewriting each item can be executed by initializing area S. For details of area S, refer to "6.16. Area S" in
Chapter 6 and "7.16. Area S" in Chapter 7.
Verification of VF66B (DC Motor Drive) Mode
Console
panel
monitor
display
Contents
Setting range (selecting item)
Setting
resolution
Initialized
data
Unit
n-00
VF66B (DC motor drive) mode
d: VF66B (DC motor drive) mode
-
d
-
VF66B (DC motor drive) mode (n-00):
The mode preset for VF66B (DC motor drive) can be verified reading out the VF66B (DC motor drive) mode
(n-00). VF66B (DC motor drive) mode (n-00) only allows to view. Modification is not allowed.
VF66B (DC Motor Drive) Models
Console
panel
monitor
display
Contents
Setting range (selecting item)
Setting
resolution
Initialized
data
Unit
n-01
VF66B (DC motor drive) models
(read-only)
2r222 through 9022
2r244 through 31544
-
Equivalent
to VF66B
(DC motor
drive) rating
-
VF66B (DC motor drive) models (n-01):
The VF66B (DC motor drive) model configured can be verified reading out the VF66B (DC motor drive) model
(n-01). The VF66B (DC motor drive) model (n-01) only allows to view. Modification is not allowed.
7R5 44
Voltage class (22: 200 V class, 44: 400 V class)
* When changing the VF66B (DC motor drive) model specified for VFC66-Z due to replacement of spare parts, etc., you
should first initialize memory. For how to initialize memory, refer to "Replace the Printed Control Board [VFC66-Z]" in
Chapter 9.
Caution
If the VF66B (DC motor drive) model configured on the control print board [VFC66-Z] does not match the VF66B (DC
motor drive) model connected with the control print board [VFC66-Z], normal control may fail and a risk of an accident
may arise. Keep this in mind.