99
Operation mode selection (i-07):
Selects operation modes (speed control (ASR)/armature current control (ACR)/armature voltage control
(AVR)/priority). It is also possible to switch via an external contact in combination with multifunction input.
Operation mode selection
*
: Speed control (ASR) mode
: Reverse direction priority for speed control (ASR) and armature current control (ACR)
: Forward direction priority for speed control (ASR) and armature current control (ACR)
: Armature current control (ACR) mode
: Contact switch for speed control (ASR)/armature current control (ACR)
: Armature voltage control (AVR)
: Reverse direction priority for armature voltage control (AVR) and armature current control (ACR)
: Forward direction priority for armature voltage control (AVR) and armature current control (ACR)
Armature Current Commanding Place Selection
Console
panel
monitor
display
Contents
Setting range (selecting item)
Setting
resolution
Initialized
data
Unit
i-08
Armature current command input place
selection
0: Analog input (1) [VFC66-Z TB1] (AIN1)
1: Analog input (2) [optional board] (AIN2)
2: Communication
option
3: Internal PLC function (high speed
operation PLCH)
4: Console panel [SET66-Z]
- 1
-
Armature current command input place selection (i-08):
Selects the armature current command input place in armature current control mode.
- For analog input (1) [VFC66-Z TB1] (AIN1) (i-08=0):
Armature current command serves as the input for [VFC66-Z TB1] (AIN1) analog input (1)
*1
.
- For analog input (2) [optional board] (AIN2) (i-08=1):
Armature current command serves as the input for [optional board] (AIN2) analog input (2)
*1
.
Speed
command
Speed
control
Armature current
command
Armature voltage
command
V
oltage c
ommand
output
i-07
Multifunction
input