115
- Data comparison function between VF66B (DC motor drive) unit and external console panel [SET66EX-Z]
(S-00=104):
The following steps show how to compare parameter data between the VF66B (DC motor drive) unit and
the external console panel [SET66EX-Z].
Connect the VF66B (DC motor drive) unit to the optional external console panel [SET66EX-Z].
Press the [MONI/FNC] key to enter the FNC (function selection) mode (LED-FNC is lit).
Select "S-00" using [
↑
][
↓
] keys ("S" starts flashing). Confirm it with the [SET] key.
Shift the target digit to the right using the [JOG/
→
] key, edit the number with [
↑
][
↓
] keys, and
enter "1040."
Subsequently confirm it with the [SET] key. If entering any value other than "1040",
is
displayed.
"S-00" is displayed again. Confirm it with the [SET] key.
Edit the number with [JOG/
→
][
↑
][
↓
] keys to enter "104", and confirm it with the [SET] key.
"ConP" and "SurE" flash alternately.
Subsequently confirm it with the [SET] key.
* If communication with the external console panel [SET66EX-Z] is disabled, there is no
response.
"ConP" is displayed. Data is compared between VF66B (DC motor drive) unit and the
external console panel [SET66EX-Z].
"End" is displayed when the data matches on both sides.
* If the setting data does not match,
flashes.
After a few seconds, mode is displayed and the monitor item returns on the display.
* If normal communication fails during the data transfer, it is aborted with mode displayed, or
flashes for 10 seconds and then the transfer is aborted.
⇒
To resume the transfer, follow the same
procedure from the beginning again after mode
is displayed.
* When connecting the external console panel [SET66EX-Z] to the VF66B (DC motor drive) unit, the console panel
[SET66-Z] located on the VF66B (DC motor drive) unit becomes unavailable.
External console panel
[SET66EX-Z]
VF66B (DC motor drive) unit
VF66B
・ ・ ・
・・・
・ ・ ・
・・・