59
command input when coupled (b-09)
0: Terminal block
1: Console panel
2: Communication option
Operation
command
input
selection
(b-11)
0: Interlock
Terminal block
[VFC66-Z TB1](ST-F)
Console panel
[START] and [FOR/REV]
keys
Communication option
Operation command
through each
communication
1: Terminal block
[VFC66-Z TB1](ST-F)
Terminal block
[VFC66-Z TB1](ST-F)
Terminal block
[VFC66-Z TB1](ST-F)
Terminal block
[VFC66-Z TB1](ST-F)
2: Console panel
[SET66-Z]
Console panel
[START] and [FOR/REV]
keys
Console panel
[START] and [FOR/REV]
keys
Console panel
[START] and [FOR/REV]
keys
3: Communication option
Communication option
Operation command through
each communication
Communication option
Operation command
through each
communication
Communication option
Operation command
through each
communication
JOG
command
input
selection
(b-12)
0: Interlock
Terminal block
[VFC66-Z TB1] (MI1 to
MI5)
*3
[Optional board] (MI6 to
MI17)
*3
Console panel
[JOG/
→
] and [FOR/REV]
keys
Communication option
JOG command through
each communication
1: Terminal block
[VFC66-Z TB1]
(MI1 to MI5)
*3
[Optional board]
(MI6 to MI17)
*3
Terminal block
[VFC66-Z TB1] (MI1 to
MI5)
*3
[Optional board] (MI6 to
MI17)
*3
Terminal block
[VFC66-Z TB1] (MI1 to
MI5)
*3
[Optional board] (MI6 to
MI17)
*3
Terminal block
[VFC66-Z TB1] (MI1 to
MI5)
*3
[Optional board] (MI6 to
MI17)
*3
2: Console panel
[SET66-Z]
Console panel
[JOG/
→
] and [FOR/REV]
keys
Console panel
[JOG/
→
] and [FOR/REV]
keys
Console panel
[JOG/
→
] and [FOR/REV]
keys
3: Communication option
Communication option
JOG command through
each communication
Communication option
JOG command through
each communication
Communication option
JOG command through
each communication
*1: When the speed/armature voltage command input selection (b-10) is set to analog input (1), you can make a
changeover in the input characteristics from "0 to ±10 V voltage input" to "0 to +10 V voltage input" or vice versa using
the Analog input (1) characteristics selection (b-17) parameter. ("0 to +10 V voltage input" is selected as the initial
setting.)
*2: When the speed/armature voltage command input selection (b-10) is set to analog input (2), you can make a
changeover in the input characteristics from "0 to ±10 V voltage input" to "0 to +10 V voltage input" or vice versa using
the Analog input (2) characteristics selection (G-03) parameter. ("0 to +10 V voltage input" is selected as the initial
setting.)
*3: The multifunction input terminal function needs to be set to JOG command [forward rotation] or [reverse rotation]. For
information on the multifunction input function, refer to "6.4. Area c" in Chapter 6 and "7.4. Area c" in Chapter 7.
Warning
[Using control input terminal [VFC66-Z TB1] (ST-F)]
When you turn on the power or perform protection reset with signals input in the control input terminal
[VFC66-Z TB1] (ST-F), the motor suddenly restarts. After checking that no signal is input in the control input
terminal [VFC66-Z TB1] (ST-F), turn on the power or perform protection reset.
Otherwise, you may be injured.