Analog Input/Output Gain and Offset Adjustment
Console
panel
monitor
display
Contents
Setting range (selecting item)
Setting
resolution
Initialized
data
Unit
L-01
Analog input (1) gain
50.00 to 150.00
0.01
Adjusted
%
L-02
Analog input (1) offset
-50.00 to 50.00
0.01
Adjusted
%
L-03
Analog output (1) gain
50.0 to 150.0
0.1
Adjusted
%
L-04
Analog output (1) offset
-50.0 to 50.0
0.1
Adjusted
%
L-05
Analog input (2) gain
50.00 to 150.00
0.01
100.00
%
L-06
Analog input (2) offset
-50.00 to 50.00
0.01
0.00
%
L-07
Analog input (3) gain
50.00 to 150.00
0.01
100.00
%
L-08
Analog input (3) offset
-50.00 to 50.00
0.01
0.00
%
L-09
Analog output (2) gain
50.0 to 150.0
0.1
100.0
%
L-10
Analog output (2) offset
-50.0 to 50.0
0.1
0.0
%
L-11
Analog output (3) gain
50.0 to 150.0
0.1
100.0
%
L-12
Analog output (3) offset
-50.0 to 50.0
0.1
0.0
%
L-13
Analog input (4) gain
50.00 to 150.00
0.01
100.00
%
L-14
Analog input (4) offset
-50.00 to 50.00
0.01
0.00
%
L-15
Analog input (5) gain
50.00 to 150.00
0.01
100.00
%
L-16
Analog input (5) offset
-50.00 to 50.00
0.01
0.00
%
L-17
Analog output (4) gain
50.0 to 150.0
0.1
100.0
%
L-18
Analog output (4) offset
-50.0 to 50.0
0.1
0.0
%
L-19
Analog output (5) gain
50.0 to 150.0
0.1
100.0
%
L-20
Analog output (5) offset
-50.0 to 50.0
0.1
0.0
%
Analog input (1) gain (L-01) to analog output (2) offset (L-17):
Setting areas for adjusting analog input/output gain and offset.
These are automatically set through analog output/input adjustment for Area S.
* For details of area S, refer to "6.16. Area S" in Chapter 6 and "7.16. Area S" in Chapter 7.
VF66B (DC Motor Drive) Operation Mode Monitor
Console
panel
monitor
display
Contents
Setting range (selecting item)
Setting
resolution
Initialized
data
Unit
L-21
VF66B (DC motor drive) operation
mode monitor
SnPL (simple mode)
FuLL (full mode)
- SnPL
-
VF66B (DC motor drive) operation mode monitor (L-21):
VF66B (DC motor drive) operation mode monitor (L-21) only allows to view.