87
Analog input (3) characteristics selection ([optional board] (AIN3))
Console
panel
monitor
display
Contents
Setting range (selecting item)
Setting
resolution
Initialized
data
Unit
G-06
Analog input (3) characteristics
selection
0: 0 to ±10 V (bipolarity)
1: 0 to 10 V (unipolarity)
2: [No function]
3: Pulse train (0 to 150 kHz)
- 1
-
Analog input (3) characteristics selection (G-06):
In this parameter, select the type of input characteristics of [option board] (AIN3). * For more information, refer
to the Optional Instruction Manual.
Analog input (3) limit settings ([optional board] (AIN3))
Console
panel
monitor
display
Contents
Setting range (selecting item)
Setting
resolution
Initialized
data
Unit
G-07
Analog input (3) upper limit speed
Absolute value of analog input (3) lower limit
speed (G-08)
to 100.0
0.1 100.0
%
G-08
Analog input (3) lower limit speed
-analog input (3) upper limit speed (G-07)
to analog input (3) upper limit speed (G-07)
0.1 0.0
%
Analog input (3) upper limit speed (G-07), analog input (3) lower limit speed (G-08):
In these parameters, set the upper and lower limits of the speed of the motor as a percentage to the maximum
speed (A-00) for when inputting the analog input that is set to the analog input (3) characteristics selection
(G-06) to [optional board] (AIN3) as a motor speed command. * For more information, refer to the Optional
Instruction Manual.
Analog output (2) characteristics selection ([optional board] (AOT2))
Console
panel
monitor
display
Contents
Setting range (selecting item)
Setting
resolution
Initialized
data
Unit
G-09
Analog output (2) characteristics
selection
0: Output voltage
1: Output current
2: Armature current command
3: Speed
4: Speed command
5: Internal PLC function
6: Calibration
7: Internal monitor
8: [For special adjustment]
- 1
-