43
Console
panel
monitor
display
Contents
Setting range (selecting item)
Factory-
initialized
data
Unit
Driving
ReWrite
J-15
Number of dynamic braking (DB)
optional units [VFDB2009] connected
-6 to -1
3
0 to 6
0 -
×
*1: For expanded options. Usually do not set this item.
*2: Provided for special adjustment. Usually do not set this item.
*3: For the number of external DB (dynamic braking) units (with communication) [VFDB2009] connected (J-15), the
absolute value represents the number of units connected. Setting a negative value enables VF66B (DC motor drive) to
be stopped when the communication with the external DB (dynamic braking) unit is disabled or the external DB
(dynamic braking) unit is in protective operation.
6.12. Area L (Setting Area for Analog Input and Output Gain)
Symbols of Driving ReWrite
: ReWrite is possible, ×: ReWrite is not possible
Console
panel
monitor
display
Contents
Setting range (selecting item)
Factory-
initialized
data
Unit
Driving
ReWrite
L-00
Vdc detection gain
80.0 to 120.0
100.0
%
×
L-01
Analog input (1) gain
50.00 to 150.00
Adjusted
%
L-02
Analog input (1) offset
-50.00 to 50.00
Adjusted
%
L-03
Analog output (1) gain
50.0 to 150.0
Adjusted
%
L-04
Analog output (1) offset
-50.0 to 50.0
Adjusted
%
L-05
Analog input (2) gain
50.00 to 150.00
100.00
%
L-06
Analog input (2) offset
-50.00 to 50.00
0.00
%
L-07
Analog input (3) gain
50.00 to 150.00
100.00
%
L-08
Analog input (3) offset
-50.00 to 50.00
0.00
%
L-09
Analog output (2) gain
50.0 to 150.0
100.0
%
L-10
Analog output (2) offset
-50.0 to 50.0
0.0
%
L-11
Analog output (3) gain
50.0 to 150.0
100.0
%
L-12
Analog output (3) offset
-50.0 to 50.0
0.0
%
L-13
Analog input (4) gain
50.00 to 150.00
100.00
%
L-14
Analog input (4) offset
-50.00 to 50.00
0.00
%
L-15
Analog input (5) gain
50.00 to 150.00
100.00
%
L-16
Analog input (5) offset
-50.00 to 50.00
0.00
%
L-17
Analog output (4) gain
50.0 to 150.0
100.0
%
L-18
Analog output (4) offset
-50.0 to 50.0
0.0
%
L-19
Analog output (5) gain
50.0 to 150.0
100.0
%
L-20
Analog output (5) offset
-50.0 to 50.0
0.0
%
L-21
VF66B (DC motor drive) operation
mode monitor
*1
SnPL (simple mode)
FuLL (full mode)
SnPL %
×
L-22
Current detection gain adjustment
95.0 to 105.0
100.0
%
×
*1: VF66B (DC motor drive) operation mode monitor (L-21) only allows to view.